Herunterladen Inhalt Inhalt Diese Seite drucken

Frozen" Appliance; Frost Protection - Pkm WA 8.5-E1614 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für WA 8.5-E1614:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3. Clean the inlet valve filter using some water.
4. Reconnect the water inlet hose to the tap and the appliance again.

5.5 "Frozen" appliance

If the ambient temperature is lower than 0
proceed as described below:
1. Disconnect the appliance from the mains.
2. Close the water tap.
3. Wash the tap with warm water so you can take the water inlet hose off.
4. Take off the hose and immerse it in warm water.
5. Pour warm water into the drum and wait approx. 10 minutes.
6. Reconnect the water inlet hose to the tap and check, that the water inlet and the
water drain works properly.
7. When you operate the appliance again, the ambient temperature must be higher
0
than 0
C.

5.5.1 Frost protection

If you have installed the appliance in a place, where the ambient temperature can
easily fall below 0
How to remove residual water in the water inlet hose:
1. Close the water tap.
2. Remove the water inlet hose from the tap and put the end into a container.
3. Select any programme except the S
4. Press the
START
approx. 40 seconds.
5. Stop the programme.
6. Connect the water inlet hose again.
0
C, always empty the inlet and outlet hoses.
/
PAUSE BUTTON
0
C and the appliance has been frozen,
programme.
PIN
and allow the programme to operate for
85

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis