Fig. 10. Adjustments «ZERO», «SPAN» and «S1».
Left: Adjustments covered by the sealing plug (4)
Right: Adjustments exposed.
Now rotate the measured device to its opposite limite position, i.e.
the position at which the KINAX 3W2 should produce the prescribed
full-scale output current (see rating plate.
Adjust the "SPAN" potentiometer with the screwdriver as before
until precisely the prescribed full-scale output current is measured
at the output.
Now recheck the zero value and readjust on the ZERO potentiometer
and then recheck the full-scale value.
10. Table 2: Specifi cation and ordering information
Description
KINAX SR 709
Features, Selection
1. Version
Standard, measuring output non intrinsically safe
Ex ia IIC T6 Gb, measuring output intrinsically safe, ATEX
Ex ia IIC T6, measuring output intrinsically safe, FTZU Czech republic
EEx ia IIC T6, measuring output intrinsically safe, Hungary
Other versions on request
IECEx Ex ia IIC T6 Gb version
2. Mounting position
Lever in spring loaded position:
Lower end position corresponding to 0/4 mA (normal)
Upper end position corresponding 0/4 mA
Later changes not possible!
3. Output signal (measuring output)
0 ... 1 mA / 3 or 4-wire connection
0 ... 5 mA / 3 or 4-wire connection
0 ... 10 mA / 3 or 4-wire connection
4 ... 20 mA / 2-wire connection or
0 ... 20 mA / 3 or 4-wire connection (adjustable with potentiometer)
4 ... 20 mA / 3 or 4-wire connection
0 ... 20 mA / 4-wire connection
DC/AC power supply only (AC/DC power supply)
Non-standard, 3 or 4-wire connection
0 ... > 1.00 to 0 ... < 20
DC/AC electrically insulated power supply only for 4-wire connection,
DC non-electrically insulated power supply for (2), 3 or 4-wire connection.
Only line D is possible for 2-wire connection in conjunction with power supply voltage 12 ... 33
(30) V DC!
Camille Bauer
8. Electric commissioning
• Provide a separate power supply for the device in case of con-
sumer loads with high interference levels.
• Install the entire plant in an EMC-compatible manner. Installation
environment and wiring can affect the EMC of the device.
• For Versions with explosion protection:

9. Maintenance

The device is free of maintenance. Repairs may only be carried
out by authorized authorities.
Order Code 709 - xxxx xx
[mA]
Operating Instructions SR709 Be – 03.13
The regulations according to EN 60079-14, the
equipment safety law, the generally acknowledged
rules of the industry and these operating instruc-
tions are applicable for installation and operation.
In order to ensure the required IP protection ca-
tegory according to EN 60529:1991 is achieved,
the cable glands must be properly installed in the
electrical operating equipment.
*Blo-
No-go with
cking
blocking
Code
A
B
B
B
B
B
C
D
Article
No./
Fea-
code
ture
709 –
1
2
6
7
9
A
0
1
A
B
C
D
E
B
F
Z
17

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis