Maintenance

About every 40 operating hours, clean the PRONTO quick-change
jaw system thoroughly and check for damage and wear.
• Inspect interchangeable inserts visually for cracks.
• Inspect the supporting jaws visually for cracks, particularly on
the lower radius.
• Retighten the mounting screws (T-nut screw connection) with
the specified tightening torque every 10,000 clamping cycles,
at the latest, or after 40 operating hours
If any cracks appear, this part must be put out of service.