5. Using the Tap
Use these buttons to scroll the menu
Use these buttons to activate and deactivate
Downloaded from
www.Manualslib.com
• 'Day' on: activates the Zip HydroTap SPARKLING on the day of the week indicated at
the selected time.
• CO
2
• Dispensing time cold: the maximum dispensing time for chilled water until dispensing
stops automatically. Adjustable between 5 and 15 seconds.
• Dispensing time hot: the maximum dispensing time for boiling water until dispensing
stops automatically. Adjustable between 5 and 15 seconds.
• Scald protection: To enable the additional scald protection, press Adjust ∧ and then
press the Safety button on the tap three times in quick succession. Scald protection
disables the boiling water function. To disable scald protection for 30 seconds, press
the Safety button three times in quick succession.
• Sleep mode: Sleep mode can be activated to save energy. If Sleep mode is enabled,
the unit will switch to Sleep if it has not been used for two hours. The water tempera-
ture will be maintained at 65°C. Operation of the tap during this time will wake the
system from sleep and the water will heat up to the set temperature again. Boiling
water is available as soon as the red LED shows a steady light.
• Filter use (days) [Info]: number of days the filter has already operated.
• Filter max. life: the maximum service life of the filter in months. The value that should
be set can be found in the filter data.
• Flush filter: if this is activated, water will be pumped through the filter to flush out a
new filter.
• Day: the current day of the week.
• Time: the current time.

Service menu (for specialists only)

Note: Do not make any changes to the settings in the Service menu unless you
are fully aware of their effects.
To open the Service menu press the Adjust ∧ and Adjust ∨ buttons simultaneously until
the current boiling water temperature and cold water temperature are shown in the
display. Use the 'Menu ∧' and 'Menu ∨' buttons to browse through the various options.
These are detailed below:
• Actual temperature values
Hot Temp: current temperature of water in the boiling water tank.
Hot Lvl: current level in the boiling water tank. Lvl1 = tank empty, Lvl2 = tank half
the selected program
full, Lvl3 = tank full
Cold Temp: current temperature of water in the cold water tank.
Cold Lvl: current level in the cold water tank. Lvl1 = tank empty, Lvl2 = tank full
• Automatic sleep mode: N/A
• Boil (sec): do not adjust (default is '6').
• Time (min) [Info]: N/A
• Correct litres: rounds the water meter down to the nearest hundred.
• Adjust boiling water temperature:
Use the Adjust ∧ and Adjust ∨ buttons to adjust the set temperature of the boiling
water between 68°C and 100°C in 0.5°C increments. CAUTION: a temperature of
more than 98.5°C is not advisable in normal conditions.
To exit the Service menu, press the Adjust ∧ and Adjust ∨ buttons simultaneously until
'Normal Operation' appears in the display.
manuals search engine
purge: purges the water from the carboniser, using carbon dioxide.