4. Installation
Filter head article number: 44115
Filter candle article number: 84500
Downloaded from
www.Manualslib.com

Optional: Installing an external ion exchanger

An external ion exchanger can be used to prevent limescale deposits in the undersink
unit and thus extend the maintenance intervals.
Note: If installing an external ion exchanger, follow the instructions supplied for
the filter head and filter cartridge.
1. Connect the filter head to the 'external filter' connections at the rear of the undersink
unit. Note the flow direction as indicated by the arrows marked on the filter head and
the label on the undersink unit.
2. Open the front cover of the undersink unit and turn the lever to the 'external filter'
position.

Commissioning

1. Before using the unit for the first time, flush through the connecting pipes and hoses
thoroughly. To flush, detach the flexible hose from the water inlet of the undersink
unit and hold it over a drain or bucket. Turn on the water and allow it to run for
several minutes. Then reattach the hose to the water inlet of the undersink unit and
check the installation for leaks.
2. Set a pressure of 2.7 bar on the pressure reducer of the carbon dioxide gas bottle.
Turn the adjusting screw anticlockwise to reduce the pressure. Turn it clockwise to
increase the pressure.
3. Check the gas-carrying connections for leaks. Caution - gas released can be very cold.
Use a leak detecting spray or soapy water so that even minor leaks will be detected.
4. If no leaks occur, plug the plug into the socket to activate the unit.
5. The screen will first display the unit model name and then the message Adjust ∧.
Press the Adjust ∧ button to start the purge cycle.
a. Carbon dioxide will discharge from the tap during this purging process.
b. This purging will stop automatically.
6. The message Adjust ∧ will appear on the display. Press the Adjust ∧ to flush the filter.
a. Allow water to flow out of the tap for about three minutes, then press the
Adjust ∧ button again to stop filter flushing.
7. Press Adjust ∧ to start temperature calibration. During this process the boiling
point of water will be determined and the boiling water temperature will be set
accordingly. Calibration takes five to ten minutes. During this time the red LED will
flash and steam may discharge from the tap.
8. The unit will then be in normal operating mode. Wait for the LED to show a steady
light, and then check the water flow and the temperature.
9. Register the appliance with the customer service department online at
www.clage.com.