5. Using the Tap

Menu

The undersink unit has a touch screen which can be used to set and read the operating
parameters. The following settings can be carried out in the menu:
'Language'
Select the language used in the menu.
'Information'
Shows data specific to the unit and any errors occurring.
'Install'
The steps that are necessary when using the unit for the first time can be viewed again
for maintenance purposes.
Flush filter – place the end of the hose located at the filter in a collecting container and
open the isolating valve on the hose before starting to flush the filter.
Reset filter – resets the filter consumption data.
Boiling point calibration – the unit determines the boiling point, which depends on the
atmospheric pressure at the installation location, and adjusts accordingly.
Booster – settings for operation of an additional instantaneous water heater to
preheat the hot water. A technical modification has to be made to the unit in order to
connect up a booster (not included in the CLAGE-range).
Light sensor calibration – the light sensor on the tap can be calibrated for the light
conditions at the installation location. This is necessary to ensure that the Sleep mode
energy-saving function operates correctly. Shield the tap from direct sunlight during
calibration.
Advanced Options – additional adjustments can be set to optimise the operation of the
appliance or reduce the noise of the fan depending on the hot water setpoint and the
environmental temperature.
• Pump vent: The hot water pump will be operated cyclically to prevent the build up of
air bubbles inside the pump.
• Power pulsing: the hot water is maintained as close as possible to the set point by
applying a closer tolerance to the set point. The appliance reheats earlier but shorter.
• Fan speed: The fan speed may be adjusted for quieter operation only if the environ-
mental temperatures are considerably lower than 35 °C.
Reset – Deactivation of the password function
'Service'
A special password specific to the unit is needed in order to access the Service menu.
Please contact Central Customer Service.
'Password'
A user password can optionally be set to lock the 'Settings' menu and prevent
unauthorised persons from altering the settings. The password should be 4 digits long.
'Radio'
N/A.
'Settings'
Date/time – set the time and the time format.
Temperature – set the water temperatures.
Filter – enter the filter data in order to calculate the remaining filter capacity.
Energy saving – the unit's heating function and chilling function can be disabled when
the unit is not in use, to reduce the energy demand. Alternatively, the boiling water
temperature can be reduced during Sleep phases for a shorter warm-up time when the