Zip HydroTap ® MINIBOIL
4. Installation
EN
10 mm hole for the bolt
Fastening
Drain
bolt
pipe bend
View from below
Filter head article number: 84519
Connecting set article number: 84521
Filter cartridge (capacity at 10 °dH)
article number: 84500 = 4200 ltr
article number: 84501 = 8500 ltr
Tap

Optional: Installing the tray

The tray (article number: 4100­44111) is an accessory which can be used to install the
tap independently of a kitchen sink.
Spacer
1. Ensure that a water supply, a drain, a socket fitted with at least a 10 A fuse and
enough room for the undersink unit are all available at the tray installation location.
Threaded rod
Spacer
2. Place the template supplied over the tray installation location.
3. Cut out the holes as indicated on the template.
4. Insert the tray. Place the plastic spacer between the worktop and the tray at the
35 mm hole. Working from below, fasten the tray to the threaded rod using the
washer and fixing nut supplied.
S/S washer
5. Install the tap as described from point 3 onwards of 'Installing the tap'.
6. If the drain bend is facing the wrong way, slacken off the fastening nut above the
Spider clamp
bend, turn it to the correct position and then tighten up the fastening nut again.
Fixing nut
7. Connect the drain bend to a siphon connecting sleeve, using a 22 mm diameter
hose. If no siphon connecting sleeve is available, use the snap connecting sleeve.
35 mm hole
a. Place the snap connecting sleeve on the side of the siphon facing the sink. Drill a
for tap
13 mm diameter hole in the drain pipe behind the snap connecting sleeve for a
drain connection. Use a suitable sealant to make a watertight seal between the
snap connecting sleeve and the drain pipe.

Installing an external ion exchanger

Hole needed for tray
recess 108 mm
An additional ion exchanger can be used to prevent limescale deposits in the
undersink unit and thus extend the maintenance intervals.
Note: If installing an external ion exchanger, follow the instructions supplied for
the filter head and filter cartridge.
Note: to flush through the ion exchanger before using it for the first time, connect
it directly to the angle valve and drain the water into a bucket or drain (depend-
ing on the size: 500 = 2-3 min, 1000 = 3-5 min).
1. Install the filter head of the ion exchanger so that it can be connected to the
pressure limiter at the isolating valve and to the filter head inlet of the regular filter.
2. Connect the pressure limiter on the isolating valve with the external ion exchanger
and connect the ion exchanger with the external filter. Use the existing hoses and
the hoses supplied and note the flow direction (arrows marked on the filter heads).

Commissioning

1. Before using the tap unit for the first time, flush through the connecting pipes and
the filter thoroughly. To flush, detach the hose from the water inlet of the undersink
unit and hold it over a drain or bucket. Turn on the water and allow it to run for
about three minutes. Then reattach the hose to the water inlet of the undersink unit
and check the installation for leaks.
2. If no leaks occur plug the plug into the socket to activate the unit.
3. The unit is now in normal operating mode. Wait for the LED to show a steady light,
and then check the water flow and the temperature.