Jungbrunnen 66-10 / 66-11
Height
Width
Depth
Weight
Supply voltage
Connected load
Power input at 100%
Standby mode
Length of the connecting lead
Light-emitting LED diodes
Test certificates awarded
Fuse
Water flow pressure minimum
Water flow pressure maximum
Water production in 24 Hours
Water production per minute
Pure water waste water ratio
Raw water need per minute
Water connection
* The flow pressure must amount to at least 150 kPa and may not
exceed 450 kPa excess pressure. If it is higher than 450 kPa excess
pressure, a pressure reduction valve must be installed.
** The flow pressure must amount to at least 150 kPa and may not
exceed 450 kPa excess pressure. If it is higher than 450 kPa excess
pressure, a pressure reduction valve must be installed.
For the connection, a tap with 3/4"
gland is required. If this is absent,
the BestWater system may only be
installed by a qualified plumber to
the drinking water pipes.
Downloaded from
www.Manualslib.com
manuals search engine
Technical information
421 mm
295 mm
430 mm
19 kg
see type plate
see type plate
170 W
< 2 W
1.8 m
Class 1
see type plate
6 A
150 kPa (1.5 bar) at 5 l /
min.*
450 kPa (4.5 bar)*
2500 litres**
1.7 litres**
1 : 1**
approx. 4.5 litres**
3/4"
The BestWater system may not be
connected to drinking water pipes
with additional check valves.
79