Connecting the discharge pipe
The SANICONDENS
Best Flat discharge connection must be connected to the flexible vinyl hose H.
®
- Unroll the flexible hose H.
- Insert the hose into the discharge connection that has a built-in non-return valve (see fig. 6).
- Position the flexible hose in the upmost vertical position possible to avoid any kinking. It is recommended to make a smooth turn to
avoid the hose from kinking.
- Secure the hose by using the clamp I supplied (fig. 6).
The hose has an inner diameter of 10 mm and can be connected to a PVC pipe of larger diameter by a plastic reducer connection J (fig.
6.1). Provide a cable tie to secure the connection (fig. 6.2).
The SANICONDENS
Best Flat is fitted with a non-return valve to prevent re-activation.
®
3.3 CONNECTING THE ALARM
SANICONDENS
®
Best Flat
level rises too high. To connect the detection system, connect the other set of cables, black and grey (see "Alarm" label), to the appliance
(refer to the instructions of the appliance). See fig. 10
NOTE: It is possible to connect the detection system to an external alarm (audible or visual, from1.5V to 230V) by changing the
connection of the detection system.
connect the external alarm, this contact must be changed to NO (normally open fig.11.3). To do this, open the cover (fig. 11.1), unplug
the grey wire from its location and plug it to the free contact above (fig. 11.2).
- ATTENTION : The maximum current admissible for our detection system is 0.5A.
- To protect the electrical components in the SANICONDENS
continuing to fill the tank comes out through the overflow outlets of the tank.

3.4 MAINS CONNECTION

Connect the power cable K to the SANICONDENS
requirements.
3.5 USE
Functional test
Before turning on the pump, make sure you remove the protective lock pin from the rear of the device. Fig. 5.
- Pour water into the tank.
- Check that the pump starts and stops when the water level drops.
- Check that there are no leaks in the connections.
Filling the neutralizer compartment
- Remove the cover from the neutralizer compartment (fig. 7).
- Add the neutralizing granules into this compartment (fig. 8).
- Reposition the cover and clip it in place.
SANICONDENS
Best Flat is ready to use. Example of an installation of a SANICONDENS
®
4
STANDARDS
SANICONDENS
Best Flat
®
5
INTERVENTIONS
Disconnect electrical supply before working on the unit !
5.1 MAINTENANCE (FIG 12)
Check the quality of the neutralizing granules regularly.
Neutralizing granules need to be replaced at least once a year. When replacing the granules, make sure to clean the compartment as well.

5.2 TROUBLESHOOTING

Fault detected
The pump doesn't start
The pump does not lift
6
GUARANTEE
Best Flat is guaranteed for 2 years for parts and labour, subject to correct installation and use of the unit.
SANICONDENS
®
is fitted with a detection system that can cut off the power supply to the connected appliance if the water
SANICONDENS
®
Best Flat (fig. 9) and then to the main power. Comply with local installation
®
conforms to the European directive on low voltage.
INSTRUCTIONS INTENDED SOLELY FOR QUALIFIED PROFESSIONALS
The pump is not connected to the power supply Plug in the unit
The lock pin has not been removed
The unit is not leveled
Power outage
Float blocked
Condensates inlet pipe blocked
Noon-return valve blocked
Discharge pipe blocked
INSTRUCTIONS INTENDED SOLELY FOR QUALIFIED PROFESSIONALS
Best Flat
is controlled by a dry contact supplied NC (normally closed). To
Best
®
Flat
Probable causes
14
, once the alarm has been triggered, any water
Best Flat : see pg. 5.
®
Action needed
Remove the lock pin
Check the unit with a leveling tool
Check the main power
Clean the tank
Clean the inlet pipe
Clean the valve
Clean the discharge pipe