Drainpipe Installation

The drainpipe is used to drain water from the
unit. Improper installation may cause unit and
property damage.
CAUTION
Insulate all piping to prevent condensation,
which could lead to water damage.
If the drainpipe is bent or installed
incorrectly, water may leak and cause a
malfunction of the water- level switch.
In HEAT mode, the outdoor unit will
discharge water. Ensure that the drain hose
is placed in an appropriate area to avoid
water damage and slippage due to frozen
drain water.
DO NOT pull the drainpipe forcefully as this
could cause it to disconnect.
NOTE ON PURCHASING PIPES
This installation requires a polyethylene tube
(outside diameter = 3.7-3.9cm, inside diameter
= 3.2cm), which can be obtained at your local
hardware store or from your dealer.
Indoor Drainpipe Installation
Drain pipe
Fig. 10.1
1. Make sure the drain pipe is connected to the
outdoor side downward.
2. The hard polyvinyl chloride(PVC)plastic pipe
(external diameter 26 mm) sold in the market
is suitable for the attached soft drain pipe.
3. Please connect the Soft Drain Pipe with the
Drain Pipe, then x it with band; if you have
to connect the Drain Pipe indoors, to avoid
condensing caused by air intake, you must
cover the pipe with heat-insulation material
(polyethylene with Speci c Gravity of 0.03, at
least 9 mm in thickness), and use Glue Band
to x it.
4. After the Drain Pipe has been connected,
5. Refrigerant Pipe and Drain Pipe should be
6. Using a 65-mm (2.5") core drill, drill a hole in
Glue
Drain pipe
Band for covering the pipe
NOTE: When drilling the wall hole, make sure
to avoid wires, plumbing, and other sensitive
components.
7. Pass the drain hose through the wall hole.
NOTE: The drainpipe outlet should be at least
5cm (1.9") above the ground. If it touches the
ground, the unit may become blocked and
malfunction. If you discharge the water directly
into a sewer, make sure that the drain has a U
or S pipe to catch odors that might otherwise
come back into the house.
95
please check if the water drains out of the
pipe e ciently and has no leakage.
heat-insulated to avoid condensing and
water-dropping later on.
the wall. Make sure that the hole is drilled at a
slight downward angle, so that the outdoor
end of the hole is lower than the indoor end
by about 1cm (0.4"). This will ensure proper
water drainage (See Fig. 10.2). Place the
protective wall cu in the hole. This protects
the edges of the hole and will help seal it
when you nish the installation process.
Wall
Outdoor
≈ 0.5~1cm
/ 0.2~0.4 inch
Fig. 10.2
Make sure the water drains to a safe location
where it will not cause water damage or a
slipping hazard.
10