Herunterladen Inhalt Inhalt Diese Seite drucken

Error Codes - Kaisai KFS-50 HRFI Bedienungsanleitung

Split-klimaanlage
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Error Codes

Inverter Split Type
Number
1
Indoor EEPROM error
2
Indoor and outdoor communication failure
Indoor fan speed malfunction
3
4
Indoor room temperature sensor open circuit or short circuit
5
Evaporator coil temperature sensor open circuit or short circuit
6
Refrigerant leakage detection malfunction
7
Communication malfunction between two indoor units (for twins model)
8
Other malfunction of twins model
Display board and main control communication failure
9
Outdoor unit malfunction
10
Current overload protection
11
Outdoor room temperature sensor open circuit or short circuit
12
Outdoor condenser pipe temperature sensor error
13
Discharging air temperature sensor error
14
Outdoor EEPROM error
15
16
Outdoor fan speed malfunction
T2b sensor error
17
Inverter module IPM protection
18
19
High/Low voltage protection
20
Compressor top overheating protection
21
Outdoor low temp. Protection
22
Compressor drive error
23
Compressor High/Low-pressure protection
Outdoor IGBT sensor error
24
Cause
84
Error
Code
E0
E 1
E3
E4
E5
EC
E8
E9
E
E
f0
f1
f2
f3
f4
f5
f6
p0
p 1
p2
p3
p4
p6
p7

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Kfs-50hrfo

Inhaltsverzeichnis