Wiring
Safety Precautions
WARNING
• Be sure to disconnect the power supply
before working on the unit.
• All electrical wiring must be done
according to local and national regulations.
• Electrical wiring must be done by a
quali ed technician. Improper connections
may cause electrical malfunction, injury
and fire.
• An independent circuit and single outlet
must be used for this unit.
another appliance or charger into the
same outlet.If the electrical circuit capacity
is not enough or there is a defect in the
electrical work, it can lead to shock, re,
unit and property damage.
• Connect the power cable to the terminals
and fasten it with a clamp. An insecure
connection may cause re.
• Make sure that all wiring is done correctly
and the control board cover is properly
installed. Failure to do so can cause
overheating at the connection points, re,
and electrical shock.
• Ensure that main supply connection is
made through a switch that disconnects
all poles, with contact gap of a least 3mm
(0.118").
modify the length of the power
DO NOT
cord or use an extension cord.
CAUTION
Connect the outdoor wires before
connecting the indoor wires.
• Make sure you ground the unit. The
grounding wire should be away from gas
pipes, water pipes, lightning rods,
telephone or other grounding wires.
Improper grounding may cause electrical
shock.
connect the unit with the power
DO NOT
source until all wiring and piping is
completed.
• Make sure that you do not cross your
electrical wiring with your signal wiring, as
this can cause distortion and interference.
Follow these instructions to prevent distortion
when the compressor starts:
TAKE NOTE OF FUSE SPECIFICATIONS
The air conditioner's circuit board(PCB) is
plug
DO NOT
designed with a fuse to provide overcurrent
protection. The speci cations of the fuse are
printed on the circuit board, such as:
Indoor unit: T5A/250VAC, T10A/250VAC.
(applicable for unit adopts R32
refrigerant only
Outdoor unit: T20A/250VAC(for <24000Btu/h
unit), T30A/250VAC(for >24000Btu/h unit)
Outdoor Unit Wiring
Before performing any electrical or wiring
work, turn o the main power to the system.
1. Prepare the cable for connection
Table 12.1: Minimum Cross-Sectional Area
99
• The unit must be connected to the main
outlet. Normally, the power supply must
have a low output impedance of 32 ohms.
• No other equipment should be connected
to the same power circuit.
• The unit' s power information can be found
on the rating sticker on the product.
)
WARNING
a. You must rst choose the right cable size
before preparing it for connection. Be sure
to use H07RN-F cables.
of Power and Signal Cables in North
America
Rated Current of
Appliance (A)
≤ 7
7 - 13
13 - 18
18 - 25
25 - 30
12
or R290
AWG
18
16
14
12
10