3.3.7.

Gas ballast

E65.R / E100.R
Loosen the connection [1]
and remove the gas ballast from the plate.
Replace the filter [2],
gasket [3] and check valve [4].
3.3.8.

Air filter (optional)

The vacuum pump must be protected from particles and liquids by means of suitable filters or
a condenser. These elements must comply with Directive 2014/34/EU: marking II 2 G IIB T4
mini and II 2 D IIIC T135°C mini according to zones.
Depending on the degree of impurities sucked in, the suction filter cartridge will clog. We recommend a
replacement at least every 1000 hours. This frequency must be adapted to suit your pumping application.
Clean the inside of the filter.
For the CHA filter: the weight of the carbon filter gives information on its operating state.

Filter type

Cartridge
126CH
848 AC
201CH
850 AC
Connect the filter to earth through the connection point to ensure ground continuity.
517976-05
EVISA ATEX E65.R / E100.R / E200.R / E300.R
E200.R / E300.R
Remove the unit [2] fitted with cap [1]
and replace the gasket [3] and check valve [4].
Replace the foam filter
positioned over the Rilsan tube.
Original weight
Critical weight
470 g.
605 g.
656 g.
845 g.
3.3.9.

Automatic drain

This drain reinjects the oil from the separating cartridges into the pump. It is located in the separating
cartridge compartment.
Operating check:
Stop the pump. Remove the plate giving access to the compartment of the separating cartridge(s). Add a
1/4 litre of oil to the drain: the float should rise. Start up the pump: the additional 1/4 litre of oil should be
sucked in, the level in the separating cartridge(s) compartment drops.
Maintenance for E65.R / E100.R:
If the operation is correct, no maintenance is necessary.
If the level does not drop after adding oil and restarting the vacuum pump, remove the float; remove the
peg and its seal, clean the hole (blowing), then reassemble the assembly.
Maintenance for E200.R / E300.R:
Remove screws [1] and take the drain assembly
out. Drive out the pin [2] then change the float
[3] and the seal [4]; clean the nozzle [5]
(blowing). Reinstall the assembly by changing
the o'ring [6].
3.3.10.

Vanes replacement

E65.R – E100.R – E200.R – E300.R:
Remove the motor and detach the 1/2 coupling sleeve from the rotor shaft
and then disassemble the lamp.
Replace the 3 sliding vanes one by one by respecting the position of the
sliding vane's chamfer, rounded shape at the rear
1
3
4
5
2
6
19