The suction gas temperature must be between +5°C and +40°C. (For temperatures outside this range,
please contact us). It is imperative to install a paper or polyester filter on the suction side, whatever the
application.
If the gas contains condensable vapours, it is imperative that the pump is equipped with an opened gas
ballast and that the pump has reached its stabilized operating temperature.
The gas sucked in by the pump must not contain liquid or solid particles, it is necessary to trap them before
the pump by filters, separators and condensers. When using a filter connected to the suction side, this filter
must be attached to the pump in such a way that no solid or liquid particles enter the pump when replacing
the filter element. Consult us.
Certain gases can be trapped before the pump by means of a carbon filter placed between the paper or
polyester filter and the application.
Some parts of the pump have surfaces where the temperature can exceed +70°C.
1.3.

Limit of services MIL'S

MIL' S company designs, produces and markets vacuum pumps in accordance with current standards.
MIL' S company only provides pump EVISA ATEX alone with the oil temperature sensor fitted
on the pump. Associated accessories (filters and hoses) are available as an option.
MIL' S company does not provide the EC marked electrical control box according to the
2014/34/EU directive.
However a standard control electrical box can be proposed, but must be installed outside the
ATEX zone by the customer.
MIL' S company never insures the installation, which must be carried out by qualified installers.
MIL' S company can provide preventive maintenance of pumps, after acceptance by the customer of a
maintenance contract.
MIL' S never provides on-call assistance.
1.4.

Characteristics table

The technical specifications described in the table below are valid only for our EVISA ATEX pumps (except
specific models) equipped with MIL'S MV99S synthetic oil, and having reached their stabilized operating
temperature.
517976-05
EVISA ATEX E65.R / E100.R / E200.R / E300.R
-1
Rated air flow
m³.h
50 Hz
1
-1
PNEUROP air flow
m³.h
50 Hz
1
-1
Air flow at 1 mbar
m³.h
50 Hz
Ultimate vacuum
mbar (HV)
1
without air ballast
Ultimate vacuum
mbar (HV)
1
with air ballast open
Maximum permissible
mbar
50 Hz
1
water vapour pressure
Water vapour
-1
kg.h
50 Hz
1
pumping capacity
Quantity of oil
Litre
2
Noise level
dB(A)
50 Hz
Supply voltage
V
50 Hz
Motor power
KW
50 Hz
-1
Rotation speed
tr.min
50 Hz
Suction port
Exhaust port
Weight with oil
kg
1
Measurement according to PNEUROP 6602 specifications at 20°C.
2
At ultimate pressure, in the open, at one meter.
(a)
Model Gas or model Dust.
(b)
Model Gas and Dust.
E65.R
E100.R
E200.R
E300.R
68
100
200
300
65
96
190
280
40
52
134
171
-2
-2
-2
-2
6.10
6.10
6.10
6.10
-1
-1
5.10
5.10
1
2
50
59
20.2
18.6
2
3.4
2.2
2.3
3
3
5
5
67
67
71
72
230/400V
230/400V
230/400V
230/400V
400/690V
1.5
2.2
4
5.5
1500
1500
1500
1500
1"1/4
1"1/4
2"
2"
1"1/4
1"1/4
2"
2"
63.4
67.2
143
172
(a)
(b)
13