7.1
TECHNICAL DATA FOR RT AND RP
Model
Weight
Nominal power
Power given to heating
Power in hot water production
Depression to chimney
Exhaust gas temperature
Exhaust gas flow
Flue dimension
System pressure (max)
Wood quantity (max)
Autonomy
Efficiency (nominal power)
Efficiency (reduced power)
CO@13% O
emissions (nom. power)
2
CO emissions (nominal power)
CO emissions (reduced power)
Dust emissions (nominal power)
NOx emissions (nominal power)
OGC emissions (nominal power)
OGC emissions (reduced power)
Electrical power
Tension
Frequency
Model
RT 60
RT 80 - RT 90 - RT 100 - RP 110
Safety distance from inflammable or sensible to heat materials in absence of other isolating systems.

7. TECHNICAL DATA

RT 60
RT 80
160 kg
18,4 kW
22,3 kW
6,5 kW
11,8 kW
15,1 kW
12 ± 2 Pa
12 ± 2 Pa
211° C
30,6 g/s
36,8 g/s
Read paragraph 2.4 of this instructions booklet
2 bar
6 Kg
60 min.
60 min.
73,8%
76,5%
0,11%
956 mg/MJ
901 mg/MJ
1058 mg/MJ
1086 mg/MJ
28 mg/MJ
24 mg/MJ
96 mg/MJ
89 mg/MJ
55 mg/MJ
52 mg/MJ
66 mg/MJ
62 mg/MJ
-
-
-
SAFETY DISTANCES
Laterally
35 cm
35 cm
99
RT 90
200 kg
225 kg
22,3 kW
7,1 kW
7,1 kW
15,1 kW
12 ± 2 Pa
193° C
193° C
36,8 g/s
2 bar
2 bar
7 Kg
7 Kg
60 min.
75,7%
75,7%
79,1%
79,1%
0,11%
0,11%
901 mg/MJ
1086 mg/MJ
1086 mg/MJ
24 mg/MJ
89 mg/MJ
52 mg/MJ
62 mg/MJ
25 W
25 W
230 V
230 V
50 Hz
50 Hz
Behind
Front
35 cm
80 cm
35 cm
80 cm
RT 100
RP 110
245 kg
230 kg
22,3 kW
22,3 kW
7,1 kW
7,1 kW
15,1 kW
15,1 kW
12 ± 2 Pa
12 ± 2 Pa
193° C
193° C
36,8 g/s
36,8 g/s
2 bar
2 bar
7 Kg
7 Kg
60 min.
60 min.
75,7%
75,7%
79,1%
79,1%
0,11%
0,11%
901 mg/MJ
901 mg/MJ
1086 mg/MJ
24 mg/MJ
24 mg/MJ
89 mg/MJ
89 mg/MJ
52 mg/MJ
52 mg/MJ
62 mg/MJ
62 mg/MJ
25 W
25 W
230 V
230 V
50 Hz
50 Hz
On
60 cm
60 cm

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Rp serieRt 60Rt 80Rt 90Rt 100Rp 110

Inhaltsverzeichnis