Herunterladen Diese Seite drucken

Novoferm iso70-1 Montage-, Bedienungs- Und Wartungsanleitung Seite 11

Vorschau ausblenden Andere Handbücher für iso70-1:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
GB
GB
OPTIONAL
Lock assembly
(14a) Press the clip 69 into the appropriate recess on the
outer handle 70 with the long square pin
(14b) Assemble the lock set on the lock section 67 as
shown in the exploded view
plate 72 with cover plate 71 from the outside into the
rectangular hole on the lock section 67 and bolt from
the inside using lock set 73 + 76 using S1. Push the
outer handle 70 through the lock 73 and bolt together
with the inside handle 78 from the inside using S2.
Caution: Rotating arm 77 (die cast zinc) must point
upwards to the right!
Garage doors without operators
(14c) Bolt the catch79 using S10 to the lock section
(14d) Hook the bolt bar 80 into the rotating arm and fasten
it with the catch 79 using S4
Middle section(s)
[1.50]
(15)
Insert the middle section(s) 86 into the angular frames 1
in the same way as the floor section 44 or lock section 67
and bolt the roller 56 and the hinges 48 using S3 (M
.
[1.50]
Top section
[1.50]
(16)
Screw the top roller bracket 88 to the top roller holder90
using S5 + S12
[1.50a]
(16a) If installing NovoPort, the outer ring on the top roller
must be removed on the drive side
top roller with your left hand and insert a screwdriver
between the rib and tooth on the roller. Twist the
roller to the right to loosen and remove the outer ring
.
[1.70c
,c
]
R
L
(16b) Insert top section 87 into angular frames 1
against falling and bolt each top roller block 88 with
top roller holder 90
using S3 (M
(M
=10Nm) to the top and middle section
A
(16c) Bolt the bottom section 44 to top section 87 and
hinges 48 using S3 (M
(17)
Adjusting the rollers:
Manual and ceiling pull operation: Pull all rollers away
from the door leaf in the direction of the arrows until the
door leaf lies flush against the frame seal (distance
between section edges and grey part of the frame seal
approx. 1 mm). The rollers must turn easily by hand.
[1.50].
Novoport: On the drive side, adjust the rollers as shown
in illustration [1.50].
Keep these installation, operating, and maintenance instructions in a safe place during the entire service life of the garage door!
. Insert the lock
[1.45 b]
.
[1.45c]
.
[1.50ab]
left and right to top section 87
R/L
=10Nm). Bolt side hinges using S3
A
=10Nm)
.
[1.50d]
A
Cable suspension
Slowly raise the garage door to its end position. Secure
(18)
door leaves against falling down
(19)
Definition of cable arrangement 12 Visible area left (red),
.
[1.45b,c]
right (black)
Both single cable ends 12 must point outwards
(20)
The double cable end 12 is inserted into the cable mount 4
without crossing the cables
(21)
Making sure they are not crossed over, the single cable
ends 12 are laid over the deflection pulley 17, which is
bolted to the moulded end piece 16
Insert the two single cable ends 12 into the cable arm of the
lower cable mount 57
[1.55d]
.
[1.45c]
Spring mount
Attach the long hole on the spring assembly 11 to the lower
(22)
spring mount 5
[1.60ab]
(23)
While lightly pre-stressing the spring assembly, hook the tip
11 into the tightening strap 12 and secure with spring pin 15!
R/L
Determine the optimum spring tension. Open the door
halfway. The door must hold in this position without help.
=10Nm)
Adjust the spring force by moving the pin in the spring
A
tightening strap 12
Caution: Don't forget to secure with spring pin 15 after
adjusting!
R/L
(24)
Install cable holder 21 in cable mount 4 using S17
(25)
Then push the two single cables 12 through the gap behind
the cable holder 21 into the grooves
. Grasp the
Rotate and bolt the guide plate 19 into the angular frame
(26)
1
R/L
guide plate only on the operator side
pull operation, do not install the guide plate
, secure
Doors without operators
R/L
(27)
Install the staple plate 93
(27a) Close the door from the inside. Hold the staple plates
.
[1.50c]
(27b) Check locking. Open and close the garage door
(27c) Attach the cable holder 91 for the manual cable 96 in
(27d) Open the door manually and mark the end position of
The manual cable must not be used when an operator is
installed!
NovoPort operator
(28)
Insert the toothed belt into the mount provided in the
moulded end piece 16
[1.70aa]
- 9 -
[1.55]
[1.55b,ba]
and move into the position shown
R/L
.
[1.60]
and secure with spring pin 15
[1.60a,aa]
.
.
[1.60ab]
.
[1.60ab]
using S13
. With a Novoport operator, install the
[1.60ba]
[1.65]
R/L
93
or 93
to the right or left of locking bolt 79 and
R
L
bolt through the two corresponding rectangular holes
(rear row of holes) of the angular frame 1
retaining plate 81 with S6 + fastening plate 82
.
[1.65a,b]
several times. When closing, locking bolt 79 must
always engage completely with staple plate 93
Adjust staple plate 93
or 93
R
Bolt securing bracket 94 to staple plate 93
S6 + S12
.
[1.65b+c]
the bottom-most section in the pre-punched holes of
the end caps S10
. Guide the manual cable 96
[1.65d]
through the appropriate hole in the cable holder 91,
secure with a knot and tie another knot to hang it
onto the connecting plate 8
the uppermost roller 90
R/L
track clamps 89 at the marked positions, and tighten
using S14. The distance between the farthest point
at the rear and the deepest point on the clamp must
be the same on the right and left sides (a=b)
+ finger protection assembly
[1.70]
[1.70a]
R/L
. (Position the side of the belt with the end clip to the
.
[1.55]
.
[1.55aa,ab]
.
using S15
.
[1.55,bb,c]
L/R
.
[1.60b]
.
[1.60b]
. With ceiling
[1.60ba]
.
[1.60ba]
/
using
R
L
.
R/L
vertically, if necessary.
L
using
R/L
.
[1.65e]
. Close the door, insert the
.
[1.65f]
[1.70]
and screw tight using S16

Werbung

loading