Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance - baltur BT 250 DSG 4T Bedienungsanleitung

Heizöl-brenner zweistufig
Vorschau ausblenden Andere Handbücher für BT 250 DSG 4T:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

CAMS REGULATION SERVOMOTOR SQM10
B
INSERTION AND DISINSERTION LEVER MOTOR
CONNECTION CAMSHAFT (1=DISINSERTION
2=INSERTION)
I
2nd FLAME AIR ADJUSTING CAM (60°)
II
TOTAL AIR CLOSURE (BURNER OFF) (0°)
III
1st FLAME AIR ADJUSTING CAM (20°)
IV
2
FLAME VALVE ACTUATING CAM (40°)
nd

MAINTENANCE

The burner does not require any particular maintenance, it is
recommended at least to carry out the following operations at the
end of the heating season:
Disassemble and carefully wash the filters, nozzle, turbulator
and ignition electrodes with solvents (gasoline, trichloroethylene,
petroleum). Use wood or plastic to clean the nozzle; avoid the
use of metal tools.
Photocell cleaning.
Have the burner and, if necessary, the chimney cleaned.
The nozzle or nozzles should be replaced at least every two
heating seasons. The replacement might be required more
frequently.
REFERENCE INDEX
CAMSHAFT
ADJUSTABLE CAMS
To modify the regulation of the cams utilized operate the
respective red rings (I - II - III...) The index of the red ring
indicate on the respective reference scale the rotation
angle taken up for each cam.
18 / 26
0006081081_201406
1
2
3

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bt 300 dsg 4t

Inhaltsverzeichnis