6. Initial operation

Multiple Power System MPS ® :
The rated capacity (max. power con-
sumption) is 27 kW / 400 V and can be
changed internally to 24 kW, 21 kW or
18 kW.
A
Sicherheitsvorschriften beachten!
Temp.
IN
Pay attention to safety instructions!
18
21
[ kW ]
[
A
DCX Next
Sicherheitsvorschriften beachten!
24
Temp.
IN
27
Pay attention to safety instructions!
11
13
[ kW ]
DCX 13 Next
A
LED
LED
LED 1
LED 2
Weitere technische Hinweise auf der Innenseite der Gerätehaube.
Further technical information on the inside of the cover.
Temp.
OUT
Fill the mains and the appliance with water and emerge air according to image
manual.
After every draining (e.g. after work on the plumbing system or following repairs to
the appliance), the heater must be re-vented in this way before starting it up again.
If the water heater cannot be put into operation, the temperature cut-out or the pres-
sure cut-out may have tripped during transport. If necessary, check that the power
supply is switched off and reset the cut-out.

Selection of power rating

Only by authorised specialist, otherwise lapse of guarantee!
Upon first connection of the appliance to the supply voltage, select the maximum
power rating.
The maximum allowable power rating at installation site depends on the local situa-
tion. It is imperative to observe all data shown in the table "Technical specifications",
in particular the required cable size and fuse protection for the electrical connection.
Moreover, the electrical installation must comply with the statutory regulations of the
®
respective country and those of the local electricity supply company (Germany: DIN
VDE 0100).
1. Select the maximum allowable power rating depending on the local situation. To do
this, take the auxiliary tool "A" from the holder on the electronics cover and turn
the switch to the desired value.
DCX Next
left stop
first click
second click 24 kW
right stop
2. Put the auxiliary tool back into the holder, connect the control panel cable to the
control panel in the hood, place the hood on the appliance and fix it with the hood
screw.
Note: The control panel cable must not be pinched or squeezed.
3. Mark the set power rating on the rating plate and slide on the faceplate from the
bottom up to the stop.
4. Switch on the power supply to the appliance.
5. After having set the maximum allowable power rating, the heating element will be
activated after approx. 10 – 30 sec of continuous water flow.
6. Open the hot water tap. Check the function of the appliance.
7. Explain the user how the instantaneous water heater works and hand over the oper-
ating instructions.
8. Fill in the guarantee registration card and send it to the CLAGE Central Customer
Q U A L I T Ä T G E P R Ü F T
Service or use the online registration.
https://www.clage.de/links/device-registration-en
Q U A L I T Y A P P R O V E D
Q U A L I T Ä T G E P R Ü F T
Q U A L I T Y A P P R O V E D
L1
L2
L3
L1
L2
DCX 13 Next
18 kW
left stop 11,5 kW
21 kW first click
13 kW
27 kW
20