7. Initial operation

EN
Multiple Power System:
The rated capacity (max. power con-
sumption) is 8.8 kW / 230 V and can be
reduced to 6.6 kW.
Before making the electrical connec tion, fill the mains and the appliance with
water by carefully opening and closing the hot water tap in order to vent com-
pletely.
To ensure a maximum flow, remove any existing aerator from the faucet. Flush
the warm and cold water pipes each at least for one minute.
After every draining (e.g. after work on the plumbing sys tem or following repairs
to the appli ance), the heater must be re-vented in this way before starting it up
again.
If the water heater cannot be put into operation, the temperature cut-out or the pres-
sure cut-out may have tripped during transport. If necessary, reset the cut-out.

Selection of power rating

Only by authorised specialist, other wise lapse of guarantee!
Upon first connection of the appliance to the supply voltage, select the maximum
power rating. Only after having set the power rating, the heater provides its standard
ope ration mode.
The maximum allowable power rating at installation site de pends on the local situa-
tion. It is impe rative to observe all data shown in the table "Technical specifications",
in particular the required cable size and fuse protection for the electrical connec tion.
Moreover, the electrical installation must comply with the statutory regulations of the
®
respective country and those of the local elec tricity supply company (Germany: DIN
VDE 0100).
1. Switch on the power supply to the appliance. The digital display on the appliance
must light up.
2. When switching on the supply voltage for the first time, the value "88" flashes in the
display. If not, please carefully read the note "Reinstallation".
3. Select the maximum allowable power rating depending on the local situation via
the up
4. Press key
5. Mark the set power rating on the rating plate.
6. Open the hot water tap. Check the function of the appliance.
7. After having set the maximum allowable power rating, the heating element will be
activated after approx. 10 - 30 seconds of water flow.
8. Explain the user how the instantaneous water heater works and hand over the
operating instructions.
9. Fill in the guarantee registration card and send it to the after-sales service or use the
online registration.
and down
arrow keys: 8.8 or 6.6 kW (display: "66") 230 V.
to confirm the setting. The appliance starts operating.