 When the User Name is set, press button E to di
If you want to modify the OFF parameter act on
buttons A (+) or B (-) to increase or decrease its
value.
 At the end of the programming of pre-infusion OFF
time on buttons A of each group, press button E
(MENU) to go to the setting of pre-infusion OFF
time of B buttons of each group.
If you want to modify the OFF parameter act on
buttons A (+) or B (-) to increase or decrease its
value.
 At the end of the programming of pre-infusion OFF
time on buttons B of each group, press button E
(MENU) to go to the setting of pre-infusion OFF
time of C buttons of each group.
If you want to modify the OFF parameter act on
buttons A (+) or B (-) to increase or decrease its
value.
 At the end of the programming of pre-infusion OFF
time on buttons C of each group, press button E
(MENU) to go to the setting of pre-infusion OFF
time of D buttons of each group.
If you want to modify the OFF parameter act on
buttons A (+) or B (-) to increase or decrease its
value.
 At the end of the programming of pre-infusion OFF
time on buttons D of each group, press button E
(MENU.)
Now there is the possibility of really enabling or
disabling the pre-infusion function during dispen-
sings.
If you want to modify the pre-infusion enabling/di-
sabling parameter, act on buttons A (+) or B (-);
0000 means that you have chosen not to use the
pre-infusion functions during dispensings, while
0001 means that you have chosen to use it.
 When you have chosen to enable or disable the
pre-infusion function during dispensing, if button
E (MENU) is pressed, the system will go to idle-
on status and TECHNICAL PROGRAMMING will
therefore be terminated.
Note: After accessing the TECHNICAL PROGRAM-
MING environment, if you want to exit you shall scroll
all menus by pressing button E (MENU) until you go
back to idle on status (Select Drink) ; no automatic
exit time-out from technical programming phase is
provided.
9.2.1.1. Reading of consumed drinks and reading
of calculated litres
There is the possibility of reading the consumed
drinks (coffee and tea) according to the procedure
described hereafter.
To access READING OF CONSUMED DRINKS and
LITRES, just press button E (exclusively from push
button panel of group 1) and keep it pressed more
than 10 seconds.
To exit from the environment of READING OF CON-
SUMED DRINKS and LITRES, press again the same
button at any time.
In this case, buttons A and B perform the special
function of incrementing/decrementing the displayed
values concerning the reading of consumed drinks.
"Cumulative Total" means the total coffee dispensings
made, i.e.the sum of all dispensings made by pres-
sing buttons A-B-C-D-E of each group.
Tea dispensings ARE NOT INCLUDED in the Cu-
mulative Total.
Dosing also offers the possibility of analyzing the
details of the total dispensings made by every single
"button" of each group.
From the "Cumulative total", by pressing button A
the total related to button A of group 1 will be di-
splayed.
Now whenever button A of group 1 is pressed, all
totals concerning the single buttons of every group
will be displayed in sequential modes (1°, 2°, 3°, 4°
and 5° button for 1°, 2° and 3° group).
If button B of group 1 is pressed, this will enable to
go back to the previous total reading.
At the end of the readings concerning the coffee
doses of every single group (button 5, group 3), the
pressure of button A will enable the user to read the
total TEA dispensings made; in this case it will be a
total as no reading division between tea1 and tea2
is provided.
If button A is pressed again, this will enable to read
the litres calculated up to that moment.