Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance At Expense Of Technicians; Technical Info; General; General Data - Dibo GreenBoiler serie Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

E N
    T E C h n I C a l I n F o

MAINTENANCE AT EXPENSE OF TECHNICIANS

For further maintenance, we advise to contact your DiBo distributor concerning
a maintenance contract. The maintenance applies to normal company
circumstances. at heavy circumstances you can communicate this so that can
be taken into account.
Remarks: It is recommend the preventive maintenance to carry out by a
competent DiBo- service technician, to be able to remain use the machine up
to maximum and also to be able to claim the guarantee conditions. To be able
to guarantee a good and regular maintenance, we advise the owner/user at
strongest to make an appointment with DiBo concerning a maintenance turn.

Technical info

GENERAL

In this chapter you find the most important technical data of the range where
your machine belongs. Machine statement ee chapter "Technical data" on
page 22 .

GENERAL DATA

• Maximum reactive force of the sprinklers: <60n
• Minimum water pressure: 200 kpa (2 bar)
• Maximum water pressure: 300 kpa (3 bar
• Minimum water temperature: 1 °C
• Maximum water temperature See "Technical data" on page 22
• Sufficient water supply at drinking water quality (Directive 98/83/EG)
• The use of an extra water filter is recommended

ACCESSORIES

1 x mounting manual

FEATURES

The high effiency burner can be executed in 5 voltages (12V/24V/230V/3x
230V/3x400V) and are standard equipped with:
• Structure: inside housing is made of stainless steel, outside housing is coated.
• Burner bottom/top: made of fireproof ceramic fiber plate.
• Coil: made of a hot spiral pipe (Ø 17 mm).
• Combustion head: consists of fuel nozzle, ignition electrodes, aluminium
burner flange with joint, steel nozzle pipe and drive disc. photo cell on top of
combustion head (no flame detection).
• Fuel pump: two pipe with built- in solenoid valve, coil 24 VaC, cable with
connector plug.
• Ignition transformer: 2x5000V complete with connecting cables.
• air blower: the blower is made of steel & equipped with an air regulating disc.
• Burner motor: Ip44, different voltages, 240W, 2750/2850 RpM.
• Burner inlet/outlet: 3/8" connection