14.5 - compressor replacement

As the compressors are hermetic, when an internal
faultoccurs, the compressor must be replaced.This must be
done as detailed below:
Disconnect the unit from the electrical supply.
Remove the access panels.
Remove the gas from the refrigerant circuit using
recovery equipment.
To avoid harming the atmosphere.
Electrically disconnect the compressor.
Unbraze the suction and discharge lines, taking care
not to damage the rest of the components.
Remove the compressor fastenings.
Replace the compressor, ensuring that it contains
sufficient oil.
Braze in the lines.
Connect the compressor according to the wiring
diagram.
Evacuate the compressor.
Introduce the quantity of refrigerant indicated on the
nameplate through the service coupling located on the
low pressure side.
NOTE: This operation must be carried out by a qualified
person.
28

14.6 - pump replacement

If the water pump needs to be replaced, proceed as
follows:
Disconnect the unit from the power supply.
Open/remove the access panel/s.
Electrically disconnect the pump.
Empty all water from the hydronic module.
Loosen the pipe unions nuts.
Replace the pump.
Tighten the pipe nuts.
Electrically connect the pump.
Connect the unit to the power supply.
Make sure the pump rotates in the right direction
using the hole in the back panel.
Reinstall the access panel.