N.B.: Always remove the pillows when adding chemical shock treat-
ment to the spa water. The pillows can be returned to the spa when
the sanitizer reading drops below 4 ppm.
To remove the pillows:
1. Grasp pillow insert (A) with finger tips and gently pry outward
from pillow base (B).
2. Grasp pillow base (B) with finger tips and gently pry outward
from spa shell (C).
3. Assemble in reverse order after cleaning.
Maintaining the cover
Using the insulating spa cover anytime the spa is not in use will
significantly reduce your operating costs, heat-up time and main-
tenance requirements.
To prolong the life of the cover, handle it with care and clean it
regularly using mild soap and water.
N.B.: Never allow anyone to stand or sit on the cover.
I
Tool Free Access Door
The Tool Free Access door provides fast access to the equipment
bay and components without the need of tools. To remove the
door, follow the steps below.
Note: To avoid any injuries, more than one individual must per-
form these steps.
1
1. Locate the door's retractable push button on the top of the
front panel (1).
2. Press the retractable push button to release the panel door
from the spa frame (2).
3. Slowly and gently tilt the panel forward to remove (3). This will
expose the equipment bay for easy access to the components.
Place the panel in a safe location to prevent from damaging it.
4.To reinstall the panel just follow the steps above in reverse order.
Panel maintenance
The panels do not require any special maintenance. To clean them,
just wipe them with a clean cloth and a neutral detergent solution.
ATTENTION: do not direct jets of water against the panels, since
electro-mechanical parts are located behind them.

Winterizing

I
®
Your Jacuzzi
Premium spa is designed to automatically protect
itself against freezing when operating properly.
I D
uring periods of severe freezing temperatures, you should
check periodically to be certain that the electrical supply to the s-
pa has not been interrupted.
In extreme, bitter cold weather less than 0°C, program the primary
filtration cycle to run for 24 hours to prevent freezing.
I
If you do not intend to use your spa, or if there is a prolonged
power outage during periods of severe freezing temperatures, it is
important that all water be removed from the spa and equipment
to protect against damage from freezing.
For expert winterization of your spa, contact your authorized
dealer.
In emergency situations, damage can be minimized by taking the
following steps:
- Disconnect the spa from the electric mains.
- Follow the directions for draining the spa.
- Get the water out of the recessed seating areas and footwell.
2
- Position the massage switch in position A (combo).
B
C
A
3
- Open the valve of the cascade with the correct knob.
- Remove the side panels and locate the drain plugs of the pumps.
Remove these plugs to allow the water to drain out of the pumps
and heater.
Use a vacuum or other means to keep the water from flooding the
system compartment.
- Replace the drain plugs.
- Loosen the hose clamp on the circulation pump intake behind the
electrical box, pull the hose off and drain it. Reinstall hose and clamp.
- Re-install cabinet panels and cover spa with the insulating cover.