Herunterladen Inhalt Inhalt Diese Seite drucken

Problem Solving; Error Code Display; Technical Specification - Merrychef Mealstream serie Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

PROBLEM SOLVING

Error code display

The Mealstream EC501 will identify some of the most common problems by flashing an error
message code in the time display window.
Error code display
Please remember - No servicing or repairs should be carried out other than by an approved Service
Engineer
Technical Specifications
Mealstream CTM3
Mealstream CTM5
Manufacturers recommended
clearances
Power Supply: See rating plate at rear of oven
This egiupment comlies with the following EEC directives:
EMC 89/336 EEC
LVD 73/23 EEC
Merrychef reserves the right to alter specifications without prior notice.
Fault
Door not fully shut.
Possible electrical fault
Oven has overheated
No time has been set.
Invalid time has been set. e.g. 61secs
Oven not heating up to
temperature
Possible component failure
Oven cavity is overheating
Possible component failure
Oven is not at correct temperature
An internal fault has been detected
Oven has overheated
The oven is switched on but the control
panel does not illuminate and fans do
not operate
Height
Width
( mm )
( mm )
640
710
640
710
690
810
16
Recommended action
Close door fully.
Call Merrychef Service Dept.
Clean air filter and vents
Leave oven switched on but not cooking
for 4-5 minutes.
Set a time
Set time in correct format 1:01
Switch off and do not use
ISOLATE FROM ELECTRICAL-SUPPLY
Call Merrychef Service Dept.
Switch off and do not use
ISOLATE FROM ELECTRICAL-SUPPLY
Call Merrychef Service Dept.
Remove food.
Wait until correct temperature light stops
flashing and stays illuminated
Call Merrychef Service Dept.
Clean air filter
Relocate oven to a position with more
ventilation
Check the fuse/circuit breakers and
electrical supply (this should be carried
out by a qualified electrician)
Microwave
Depth
Wt.
Power output
( mm )
( kgs)
( watts )
630
90
1425
630
90
1425
680
.
Convection
Power output
( kw )
2.5
3.0
Pt No. 32Z3313 Issue 05

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Mealstream ec501Mealstream rd501

Inhaltsverzeichnis