5 MAINTANANCE - GARBAGE MANAGEMENT -
DISPOSAL OF MATERIALS
Prior to undertaking any maintenance or cleaning please make sure the electrical supply is disconnected from
the equipment. Maintenance must be carried out by suitably qualified and licensed persons.
Only qualified technicians should undertake service on the appliance.
Disconnect the appliance from the power supply before cleaning or maintenance.
Do not allow children to operate or carry out any cleaning to the appliance.
The appliance contains a refrigerant that requires by law a Special licensed person carry out any repairs to
the refrigeration equipment. Refrigerant must not be vented to the atmosphere.
Clean the door gaskets on a regular basis to ensure hygiene and long life.
CAUTION
All cleaning ordinary and extraordinary operation are described in chapter "3 CLEANING" Pag. 32

5.1 PERIODICAL CHECKS

At regular intervals (at least once a year), it is important to make a complete system check by qualified staff only.
Please check that:
the water drainage system works properly.
there are no refrigerating gas leaks and the complete refrigerating system works properly.
the maintenance state of the electrical system is completely safe.
the door gaskets and the door itself close properly.
the condenser of refrigerating unit is clean.
the correct setting of the electronic controller.
5.2 REPLACEMENT OF THE LIGHT
The fluorescent lamps, include the information that the lamps have to be replace by identical lamps only.
See the max lamps power identification label near the lamps.
The electric power supply must be switch-off, by disconnecting the Counter or by opening the switch You find
at the top of principal electric supplier whenever it is necessary to change the lamps.
To remove the lamp take the plastic protection of the lamp off and size it at the two ends. Move it 90° round
till You hear a click. Replace the lamp paying attention not to break it. Install the new lamp following the same
instructions and cover it again with the protection.
5.3 SUBSTITUTION OF THE FAN MOTOR
If the device is provided with a fan motor and it is necessary to remove it, it is important to taking off the ten-
sion, verify the label with technical data of the fan motor and substitute it with one of identical power, voltage
and frequency.
5.4 SUBSTITUTION OF THE COMPRESSOR/ Refrigerated gas
In case of compressor damaging and/or replacing, save its refrigerating gas and oil and avoid dispersing it in the
environment.