1.5 POSITIONING AND FEET REGULATION
1.6 INSTALLATION INSIDE YOUR SHOP/RESTAURANT /WORKROOM
It is advisable to install the refrigerated table inside an area with an air conditioning system. Please note that
malfunctions may arise in areas that are not provided with air conditioning, e.g. condensation formation.
ATTENTION
In order to allow a good functioning of the Counter please draw attentions to the following instructions:
• Do not position the unit in an area directly exposed to sun light or to other heating sources,
such as high intensity incandescent lighting systems, ovens or other radiant heating sources, e.g. heating
radiators etc.
• Do not position the unit nearby door openings producing air currents, whether doors or win-
dows or directly exposed to air from fans, vents or fan coil unit air conditioner.
• Do not block or obstruct the air inlets of the built-in refrigeration unit.
• Do not place any objects on the unit, including boxes or any other type of objects; leave the entire
perimeter of the unit completely free so that air can circulate properly.
• Do not place the Refrigerated Counter inside areas with high relative humidity levels (it may
cause formation of condensation)
• Do not position the refrigerated table inside a closed niche, as there is not enough air circulation
and may cause the refrigeration unit to not work properly.
• Don not place the unit one above another.
• Verify that the room in which the Counter is placed must be sufficiently aired, even when the
shop is closed.
Verify that in the installation room there is enough air turnover, even during closing and rest hours. In
this way the expansion/condensing unit will work correctly.
1.7 WALL MINIMUM DISTANCE
In order to allow a good performance of the Counter, during the installation you must respect the MINIMUM
WALL distances as indicated below.
Keep a MINIMUM distance of 60 cm from the front part of the motor grill of the unit
Keep a MINIMUM distance of 10 cm from the back of the unit to the wall; this will prevent formation of condensation.
Pizza Refrigerated Counters | User and Maintenance Manual | EN
Place the Counter in a perfect horizontal position, acting if necessary on the screw type
adjustable feet. Use a spirit level to check it. The Counter must be placed in order to
operate properly and allow the correct defrost condensate water draining. In this way
you will avoid noisy vibrations of the condensing unit. Check the correct positioning of
the condensate water basin and its draining.