6.2 Indirect calibration

A value from the following table is to be added to the
default factory calibration value in the display. To
reset the pump to the factory calibration value, acti-
vate the "DEFAULT" function, see section 4.7.
To use the values, the following must be fulfilled:
• The viscosity and density of the liquid to be dosed
must not differ considerably from water at 20°C.
• A GRUNDFOS installation kit or corresponding
foot valve, injection valve and hose diameter must
be used.
• The length of the dosing hose must not exceed
6 metres.
• The suction lift must lie between 0.1 and 1.5 me-
tres.
Values to be added to the calibration value at various counter pressures [bar]
Pump type
0-1
DMS 2
1.4
DMS 4
2.2
DMS 8
2.0
DMS 12
1.3
Adding the value:
Fig. 11
1-2
2-3
3-4
1.1
0.8
0.5
1.6
1.0
0.3
1.2
0.4
-0.4
0.4
-0.4
-1.3
Set value
to table value
+ display value
Operating display
4-5
5-6
6-8
0.2
-0.2
-0.6
-0.3
-1.0
-1.9
-1.2
-2.0
-
-
-
-
Operating display
without changes
8-10
10-12
-1.2
-1.8
-3.2
-
-
-
-
-
19