Herunterladen Inhalt Inhalt Diese Seite drucken

Indirect Calibration - Grundfos DME 12 Montage- Und Betriebsanleitung

Vorschau ausblenden Andere Handbücher für DME 12:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 30

6.2 Indirect calibration

A value from the following table is to be added to the
default factory calibration value in the display. To re-
set the pump to the factory calibration value, activate
the "DEFAULT" function, see section 4.17.
To use the values, the following must be fulfilled:
• The viscosity and density of the liquid to be dosed
must not differ considerably from water at 20°C.
• A Grundfos installation kit or corresponding foot
valve, injection valve and hose diameter must be
used.
• The length of the dosing hose must not exceed
6 metres.
• The suction lift must lie between 0.1 and 1.5 me-
tres.
Values to be added to the calibration value at various counter pressures [bar]
Pump type
0-1
DME 2
1.4
DME 8
3.5
DME 12
2.1
DME 19
18.3
12.2
DME 48
24.3
Adding the value:
Fig. 25
1-2
2-3
3-4
4-5
1.1
0.8
0.5
0.2
2.7
2.0
1.2
0.4
1.3
0.4
-0.4
-1.3
6.1
0
-6.1
8.3
-8.3
-
Set value
to table value
+ display value
5-6
6-8
8-10
-0.2
-0.6
-1.2
-0.4
-1.6
-3.1
-2.1
-3.4
-
-12.2
-21.4
-
-
-
-
-
Operating display
10-12 12-14 14-16 16-18
-1.8
-2.4
-3.0
-
-
-
-
-
-
-
-
-
-
-
-
Operating display
without changes
-3.6
-
-
-
-
27

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dme 19Dme 48

Inhaltsverzeichnis