Herunterladen Inhalt Inhalt Diese Seite drucken

Programming The Control Unit - V2 TORQ-D Serie Handbuch Für Den Installateur

Elektromechanischer irreversibler schiebetorantrieb 24v für tore bis 500 kg gewicht
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 134
12 - PROGRAMMING THE CONTROL
UNIT
-PrG
The configuration menu
items; the display shows the selected item.
i
By pressing
, you will pass to the next item; by pressing
will return to the previous item.
By pressing OK, you can view the current value of selected item
and possibly change it.
End
The last menu item (
) allows storing the carried out changes
and going back to the control unit normal operation.
You must exit from programming mode through this menu item if
you do not want to lose your configuration.
m
WARNING: in case no operation is carried out for more
than one minute, the control unit exits from the
programming mode without saving any of your setups and
changes, which will get lost.
PARAMETER
VALUE
dir
dX
SX
EnSA
no
Si
P.APP
0 - 100
t.PrE
0.5" - 1'00
no
t.PCh
0.5" - 1'00
no
consists in a list of configurable
h
, you
DESCRIPTION
Gate direction (the direction you see from the inside)
The gate opens rightwards
The gate opens leftwards
Energy saving function
This function is useful for reducing the energy consumption of the
automation device while in stand-by mode.
If the function is enabled, the control unit will enter ENERGY
SAVING mode under the following conditions:
• 30 seconds after completion of an operational cycle
• 30 seconds after an opening (if automatic closure is not enabled)
• 30 seconds after exiting the programming menu
In ENERGY SAVING mode, power to the accessories, display,
flashing lights and closure electromagnets is deactivated.
ENERGY SAVING mode is exited:
• If an operational cycle is activated
• If one of the keys on the control unit are pressed
Function deactivated
Function activated
Partial opening
The percentage of the path the gate performs in the case of opening
using the Pedestrian Start command
Pre-blinking time
Before any gate movement, blinker will be activated for
warn about the incoming motion (adjustable time from 0.5" to 1'00)
Function deactivated
Different closing pre-flashing time
If this parameter has a value assigned to it, the control unit will activate
pre-flashing prior to closure for the length of time set in this menu
(adjustable time from 0.5" to 1'00)
The closing pre-flashing time corresponds to
i
By holding down the
End
scroll fast, until item
In this way, you can quickly reach either the top or bottom of the
list.
-PrG
t.PrE
t .PrE
- 44 -
h
or
keys, configuration menu items will
is viewed.
End
dir
En.SA
DEFAULT
dX
no
25
1.0"
time, to
no
MEMO

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Torq500d-24vTorq400d-24v-f

Inhaltsverzeichnis