Herunterladen Inhalt Inhalt Diese Seite drucken

V2 TORQ-D Serie Handbuch Für Den Installateur Seite 47

Elektromechanischer irreversibler schiebetorantrieb 24v für tore bis 500 kg gewicht
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 134
PARAMETER
VALUE
Pot
30 - 100
P.rAL
0 - 70
SPUn
no
Si
rAM
4 - 0
(STD)
6 - 0
(FAST)
SEnS
no
1.0A-15.0A
1.0A-18.0A
rA.AP
0 - 100
rA.Ch
0 - 100
St.AP
PAUS
ChiU
no
St.Ch
StoP
APEr
St.PA
ChiU
no
PAUS
DESCRIPTION
Motor power
The displayed value is the percentage of max. motor power
Power motor during slow-down phase
The value displayed represents the percentage of the maximum
motor power
Start off
If this function is activated, for the first 2 seconds of motion of each
door, the control unit will ignore
maximum power command in order to overcome the gate inertia
Function deactivated
Function activated
Starting ramp
In order not to stress too much the motor, when the motion starts
the power is gradually increased, until reached the set value or 100%
if the take-off is enabled.
Higher is the set value, longer the length of time of the ramp, that is
the time necessary to reach the value of nominal power.
Adjusting the obstacle sensor
Function deactivated
This menu allows adjustment of the sensitivity of the obstacle sensor.
(STD)
When the current absorbed by the motor exceeds the value set, the
(FAST)
control unit detects an alarm
Slow down in opening
This menu allows regulating the percentage of the ride/drive that is
carried out at reduced speed during the last opening stretch
Slow down in closing
This menu allows regulating the percentage of the ride/drive that is
carried out at reduced speed during the last closing stretch
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the opening phase
The gate stops and goes to pause
The gate immediately starts closing
The gate go on with the opening phase (command is ignored)
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the closing phase
The gate stops and its cycle is considered as finished
The gate opens again
Start command during the pause
This menu allows fixing the control unit conduct in case it receives a
Start command when the gate is open during its pause phase
The gate starts closing
Command is ignored
The pause time is reset (
Pot
value and it will give motor the
Ch.AU
)
- 45 -
DEFAULT
MEMO
60
(STD)
100
(FAST)
20
no
2
(STD)
3
(FAST)
no
15
(STD)
25
(FAST)
15
(STD)
25
(FAST)
PAUS
StoP
ChiU

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Torq500d-24vTorq400d-24v-f

Inhaltsverzeichnis