Installation instructions
Steam cooker
Type of construction 60-381
Model 698
General notes
Installation instructions
If fitting in flammable material, the NIN regulations and the fire protection guidelines from the Swiss Association of
Cantonal Fire Insurance Companies must be strictly observed, as must therequirements of the relevant fire authorities
Electrical connections
Electrical connections must be established by trained electricians in accordance with the
regulations of NIN and the local electricity supply companies.
A mains isolating device with 3 mm contact opening should be provided in the house
wiring system. Switches, plug and socket devices, circuit breakers and fusible cut outs
which are accessible after installation and which have all poles switching are permis
sible as isolating devices.
Effective earthing and separately installed neutral and earth conductors (schematic
diagram TN S) ensure safe and fault free operation.
Existing installations should always be checked.
Type of connection, connector plug type 12, pre-assembled
Model no.
Load voltage 230 V 230 V~ 50 Hz
Fuse protection
10 A
Connected load
2200 W
698
J698.50 1
26.5.08 ITH