4.2. Operation
When the running speed of the generating set has stabilised (approximately 3 minutes):
Check that the circuit breakers (fig. A - mark 10) are pushed down. Press if necessary .
Connect the appliances that are to be used to the electrical sockets (fig. A - mark 11) of the generating set.
The working hours counter (fig. A - mark 14) shows the number of hours that the generating set has worked.
This generating set has an automatic idling system through the hare-tortoise switch (fig. A – mark 8).
Hare position
The engine speed stays at its operating speed.
N. B. : When the generating set is started up, regardless of the position of the hare – tortoise switch, the engine speed will be the operating speed.

4.3. Switching off

Disconnect the electrical sockets (fig. A - No. 11) allowing the engine to run idle for 1 or 2 minutes.
Turn the MODYS key (fig A - No. 9) to "OFF" : The generating set stops.
Close the fuel tap (fig. A - No. 6 & fig. C - No. 1).
Always ensure suitable ventilation for the generating set.
Even after shut down, the engine continues to dissipate heat.
Warning

5. Safety features

5.1. Circuit breaker

The set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the event of an
overload and/or short circuit, the supply of electrical energy may be cut.
If necessary, replace the circuit breakers in the generating set with circuit breakers with identical nominal ratings and specifications.
5.2. Oil cut-out
If there is no oil in the engine sump or if the oil pressure is low, the oil safety mechanism automatically stops the engine to prevent any damage.
If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.

6. Maintenance schedule

6.1. Reminder of use
The maintenance operations to be carried out are described in the maintenance schedule. The interval for this is supplied as a guide
and for generating sets operating with fuel and oil which conform to the specifications given in this manual.
If the generating set is used under extreme conditions, the interval between the maintenance operations must be shortened.
6.2. Maintenance table
Component
carried out when the
expiry date is reached
Screws and bolts
Engine oil
Oil filter
Fuel filter
Air filter
Starter battery
Spark plugs
Generating set
Valves*
Starter*
* Operation(s) to be entrusted to one of our dealers. ** Foam element. *** Paper element.
If used in dusty conditions, clean the air filter more frequently.
Operations to be
Each time it is
Check
Check the level
Change
Replace
Replace
Check
Clean**
Replace***
Check
Check - Clean
Replace
Clean
Have checked*
Have checked*
The engine speed slows down after 2 minutes of operation.
When it's operating the engine speed returns automatically to its
Every
Year
used
Or
every 25 hours
•**
Tortoise position
operating speed.
Every
Every
Year
Year
Or
Or
every 100
every 200
hours
hours
•***
Every
Year
Or
every 500
hours
•*
•*