6.3 Installing the motor

When connecting motors via brackets or an IEC flange, a suitable IP65 seal must be provided. The customer is
Ex
responsible for fitting this seal.
The ventilation openings in the fan hood must not be blocked.
For sufficient cooling, the distance between the hood and the wall must not fall below the FB measurement. FA is
the minimum distance required to remove the fan hood.
Motor size
FB (mm)
FA (mm)
Motor size
FB (mm)
FA (mm)

6.4 Cable glands

Motors can be fitted with the following cable entry points:
Frame
63-71
80-132S
132M-160
Cable glands must comply at least with the motor protection class specified on the model plate.
Unused cable glands must be closed depending on the type of motor protection. Existing plugs must be tighte-
ned firmly.

6.5 Electrical connection

Please refer to the rating plate and these operating instructions as well as the current catalogue for technical data
and information on the permissible operating conditions. You will find information on special versions on your
order confirmation. If anything is unclear, we urgently recommend you to contact the factory or your sales centre
giving the model description and the serial number.
Motor 0.12 - 4.0 kW
Connect the protective earthing conductor to this terminal.
Cyclostraße 92
85229 Markt Indersdorf
Phone +49 (0) 8136 66 0
63-71
80
90
100
20
20
20
20
48
49
52
56
63-71
80
90
100
20
20
20
20
61
93
115
121
Conduit threat
1 x M16 x 1,5 1 x M25 x 1,5
2x M25 x 1,5
2 x M32 x 1,5
E-Mail: marktind@sce-cyclo.com
www.sumitomodriveeurope.com
Standard motor
112-132S 132M-160M
20
25
60
75
Brake motor
112-132S 132M-160M
25
25
132
170
Frame
180
200-225
250
Motor 5.5 - 55 kW
D6000_DEU_ENG_01_2010_2.0_991179
FA or FB
160L
180M
180L
220
30
30
30
30
130
155
170
230
160L
180M
180L
220
30
30
30
30
220
367
370
445
Conduit threat
2 x M 40 x 1,5
2 x M50 x 1,5
2 x M63 x 1,5
25