Herunterladen Inhalt Inhalt Diese Seite drucken

Mitsubishi Electric ME-RTU Bedienungsanleitung Seite 303

Inhaltsverzeichnis

Werbung

IMPLEMENTATION TABLE
OBJECT GROUP & VARIATION
Object
Number
21
21
21
21
21
21
21
22
22
22
22
22
23
23
23
23
23
30
30
30
30
ME-RTU Remote Terminal Unit
Variation
Description
Number
Frozen Counter –
0
Any Variation
Frozen Counter –
1
32-bit with flag
Frozen Counter –
2
16-bit with flag
Frozen Counter –
5
32-bit with flag
and time
Frozen Counter –
6
16-bit with flag
and time
Frozen Counter –
9
32-bit without flag 1
Frozen Counter –
10
16-bit without flag 1
Counter Event –
0
Any Variation
Counter Event –
1
32-bit with flag
Counter Event –
2
16-bit with flag
Counter Event –
5
32-bit with flag
and time
Counter Event –
6
16-bit with flag
and time
Frozen Counter
0
Event – Any
Variation
Frozen Counter
1
Event – 32-bit with
flag
Frozen Counter
2
Event – 16-bit with
flag
Frozen Counter
5
Event – 32-bit with
flag and time
Frozen Counter
6
Event – 16-bit with
flag and time
Analog Input - Any
0
Variation
Analog Input –
1
32-bit with flag
Analog Input –
2
16-bit with flag
Analog Input –
3
32-bit without flag 1
REQUEST
Outstation parses
Function Codes
Qualifier Codes
(dec)
(hex)
00, 01 (start-stop)
1
(read)
06 (no range, or all)
22 (assign class)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
1
(read)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
1
(read)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
1
(read)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
1
(read)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
(read)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
(read)
07, 08 (limited qty)
17, 27, 28 (index)
06 (no range, or all)
1
(read)
07, 08 (limited qty)
06 (no range, or all)
1
(read)
07, 08 (limited qty)
06 (no range, or all)
1
(read)
07, 08 (limited qty)
06 (no range, or all)
1
(read)
07, 08 (limited qty)
06 (no range, or all)
1
(read)
07, 08 (limited qty)
06 (no range, or all)
1
(read)
07, 08 (limited qty)
06 (no range, or all)
1
(read)
07, 08 (limited qty)
06 (no range, or all)
1
(read)
07, 08 (limited qty)
06 (no range, or all)
1
(read)
07, 08 (limited qty)
06 (no range, or all)
1
(read)
07, 08 (limited qty)
00, 01 (start-stop)
1
(read)
06 (no range, or all)
22 (assign class)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
1
(read)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
1
(read)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
(read)
07, 08 (limited qty)
17, 27, 28 (index)
RESPONSE
Outstation can issue
Function Codes
Qualifier Codes
(dec)
(hex)
00, 01 (start-stop)
129 (response)
17, 28 (index)
00, 01 (start-stop)
129 (response)
17, 28 (index)
00, 01 (start-stop)
129 (response)
17, 28 (index)
00, 01 (start-stop)
129 (response)
17, 28 (index)
00, 01 (start-stop)
129 (response)
17, 28 (index)
00, 01 (start-stop)
129 (response)
17, 28 (index)
129 (response)
17, 28 (index)
130 (unsol. resp)
129 (response)
17, 28 (index)
130 (unsol. resp)
129 (response)
17, 28 (index)
130 (unsol. resp)
129 (response)
17, 28 (index)
130 (unsol. resp)
129 (response)
17,28 (index)
130 (unsol. resp)
129 (response)
17,28 (index)
130 (unsol. resp)
129 (response)
17,28 (index)
130 (unsol. resp)
129 (response)
17,28 (index)
130 (unsol. resp)
00, 01 (start-stop)
129 (response)
17, 28 (index)
00, 01 (start-stop)
129 (response)
17, 28 (index)
00, 01 (start-stop)
129 (response)
17, 28 (index)
A - 49

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis