Emptying the collection container
See graphics pages for illustration
1. Switch the device off and disconnect it
from the power supply.
2. Unlock the locking clips.
Illustration E
3. Remove the container lid and put it to
one side.
4. Remove the suction hose from the suc-
tion hose connection.
5. Remove the container from the base
plate and empty.
6. Dispose of or reuse the contents in ac-
cordance with statutory regulations.
7. Place the container on the base plate.
8. Insert the suction hose into the suction
hose connection.
9. Replace the container lid and check it for
a correct fit.
10.Lock the locking clips.

Finishing operation

1. Switch off the device using the On/Off
switch
2. Empty and clean the collection contain-
er.
3. Remove the accessories and clean and
dry them as necessary.

Transport

CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during
transport and storage.
1. When transporting in vehicles, secure
the device against slipping and tipping
over according to the applicable guide-
lines.

Storage

CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during
transport and storage.
1. Store the device indoors only.
12

Care and service

 Rinse off the device and accessories at
regular intervals using a suitable liquid
and allow to dry.
 Check the cartridge filter regularly for
damage. Replace the cartridge filter if
damaged.
Replacing the cartridge filter
See graphics page for illustrations
Illustration F
IVR-B 30/15, IVR-B 50/30
Cartridge filter
1
Washer 4x
2
4x nuts
3
Illustration G
IVR-B 20/8
Cartridge filter
1
Washer
2
Nut
3
1. Unscrew the nut(s) and remove the
washer(s).
2. Remove the cartridge filter.
3. Insert the new cartridge filter.
Ensure that the filter is inserted correctly
and that the earth cable is connected
during installation.
4. Insert the washer(s) and nut(s).
5. Tighten the nut(s).

Troubleshooting guide

DANGER
Risk of injury
Danger of the device unintentionally start-
ing and danger of electric shock
Switch off the device and unplug the mains
plug before performing any work on the de-
vice.
Have all checks and work on electrical
parts performed by an qualified technician.
The motor (suction turbine) does not
start up
No electrical voltage present
 Check the socket and the power supply
fuse.
 Check the mains cable and the mains
plug of the device.
English