Herunterladen Inhalt Inhalt Diese Seite drucken

Finishing Operation; Transport; Storage; Care And Servicing - Kärcher IVR 100/24-2 Ef Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Finishing operation

1. Switch off the device using the On/Off
switch
2. Empty and clean the collection contain-
er.
3. Remove the accessories and clean and
dry them as necessary.

Transport

CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during
transport and storage.
1. When transporting in vehicles, secure
the device against slipping and tipping
over according to the applicable guide-
lines.

Storage

CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during
transport and storage.
1. Store the device indoors only.

Care and servicing

1. Rinse off the device and accessories at
regular intervals using a suitable liquid
and allow to dry.
2. Check the bag filter regularly for dam-
age. Replace the bag filter if damaged.
Replacing the filter
See graphics page for illustration
Illustration G
1. Unscrew the screw plug.
2. Remove and replace the filter.
3. Insert the new filter.
Ensure that the filter is inserted correctly
during installation.
4. Screw in and tighten the screw plug.
Replacing the bag filter
See graphics page for illustrations
Illustration H
Screws
1
Tensioning ring
2
Bag filter
3
Cleaning device
4
14
1. Remove the suction head.
(see chapter Removing the suction
head)
2. Remove the filter inlay by the handles
and turn it around.
Illustration I
3. Remove the screws and disassemble
the cleaning device.
4. Loosen the tensioning ring screws.
5. Remove the bag filter.
6. Dispose of the foam filter.
7. Insert the new bag filter.
8. Insert the new foam filter.
9. Fit the tensioning ring and screw it in
place.
10.Fit the cleaning device and screw it on.
11.Insert the filter inlay.
In doing so, make sure the tab on the fil-
ter inlay fits into the shaft.
Illustration J

Troubleshooting guide

DANGER
Risk of injury
Danger of the device unintentionally start-
ing and danger of electric shock
Switch off the device and unplug the mains
plug before performing any work on the de-
vice.
Have all checks and work on electrical
parts performed by an qualified technician.
The motor (suction turbine) does not
start up
No electrical voltage present
 Check the socket and the power supply
fuse.
 Check the mains cable and the mains
plug of the device.
The suction power decreases
Nozzle, suction hose or suction pipe
clogged.
 Check the nozzle, the suction hose and
the suction pipe and clean if necessary.
The filter is dirty.
 Clean the filter.
Customer Service department
If the malfunction cannot be corrected, the
device must be checked by the Customer
Service department.
English

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis