"CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY"
1 Legend of symbols
This symbol tells you what to say to the end-users.
This symbol tells you that the sections concern safety issues.
This symbol tells you what to say to the end-users.
2 Intended use and restrictions
2.1 Intended use
The ZA4N control panel is designed to control the 230V ATI, FERNI, KRONO, FAST and FROG swing gate operators.
The use of this product for purposes other than those described above and installation executed in a manner other than as
instructed in this technical manual are prohibited.
2.2 Limits to use
The overall power of the motors must not exceed 600W.
3 Reference standards
For its quality processes management Came Cancelli Automatici is ISO 9001 certified, and for its environmental management it is
ISO 14001 certified. CAME engineers and manufactures all of its products in Italy.
This product complies with the following standards: see declaration of conformity.
4 Description
This product is engineered and manufactured by CAME CANCELLI AUTOMATICI S.p.A. and complies with current safety regulations.
Guaranteed 24 months if not tampered with.
The control panel works on 230V a.c. of power, 50/60Hz frequency.
The control devices and accessories are powered by 24V. Warning! The accessories must not exceed 20W overall.
All connections are protected by fast fuses, see table.
The board performs and controls the following functions:
- automatic closing after an opening command;
- pre-fl ashing of the fl ashing light;
- adjusting the motor torque on the connected automation device.
The command modes that may be defi ned are the following:
- opening/closing;
- opening/closing with maintained action;
- complete stop.
Following an obstacle detection, the photocells can:
- reopening if the gate is closing.
Expressly fi tted trimmers adjust:
- duration of theautomatic closing;
- M2 gearmotor closing delay;
- operating time.
It is also possible to connect:
- signalling lamp - gate open.
FUSES TA BL E
protection:
Control board (line)
Control devices and accessories
(control unit)
"IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS"
"THIS MANUAL IS ONLY FOR PROFESSIONAL OR QUALIFIED INSTALLERS"
fuse for:
5A-F
1A-F
T E CH NICA L F EAT U RES
power supply 230V - 50/60Hz
max power 600W
max power of 24V accessories 20W
insulation rating
casing material ABS
casing protection rating IP54
operating temperature -20 / +55°C