Herunterladen Inhalt Inhalt Diese Seite drucken

FARFISA INTERCOMS ZHEROS ZH1252B Handbuch Seite 15

Video-gegensprechanlage mit farbbildschirm für das digitale duo-system
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 33
To associate the ringtone to the type of call, press for a
long time key:
to associate it to the call from external station
to associate it to the call from intercommunicating
block of fl ats
to associate it to the call from fl oor
to associate it to the call from intercommunicating
apartment
3.2.6 Exit from the ringtone programming mode
Wait about 10 seconds without pressing any key; the device
exits automatically from the programming mode and icon
turns off.
4. PROGRAMMING
To function properly, the video intercom must be programmed;
if no special performance are required the only needed
programming is that related to the user address, in this case
pass directly to paragraph 4.2.1 User Address and number
of room.
Attention: the programming must be performed by expert
(installer), incorrect programming can prevent proper
operation of the entire video intercom system.
4.1 System programming
The programming that can be performed are:
- addresses associated to the key
- address associated to the key
- call re-launch address from fl oor
- secondary addresses of the video intercom
For programming, follow the methods described in the
following paragraphs.
4.1.1 Entering into the system programming
For accessing to the system programming jumper J4 must
be moved from position 2-3 to position 1-2; icon
4.1.2 Addresses associated to
To key
can be associated 1 address of apartment and
of room for intercommunicating calls, or 1 actuator address
or up to 4 addresses of external stations to be able to control
them in sequence.
- Programming Building Intercommunicating Address:
with microswitches SW1 set the address of the desired
apartment and with microswitches SW2 set the room
number 0 (see table on page 39); press for a long time
key
until a tone will confi rm the occurred storing.
- Programming Apartment Intercommunicating Address:
with microswitches SW1 set the address of your apartment
and with microswitches SW2 set room number, from 0 to
3 (see table page 39; press for a long time key
a tone will confi rm the occurred storing.
- Programming Actuator Address:
with microswitches SW1 set the actuator address which is
intended to control (from 211 to 230) and with microswitches
SW2 set the room number 0 (see table on page 39);
press for a long time key
occurred storing.
- Programming External Station Addresses:
in the key
, it is possible to programme up to 4 addresses
lights up.
key
until
until a tone will confi rm the
of external stations with which it will be connected in
sequence at each pressure of the key. With micro-switches
SW1 set the address of the fi rst external station, and set 0
on microswitches SW2, (see table on page 39); press for
a long time key
storing of the fi rst address. If it is intended to programme
a second address, it is necessary to set microchips SW1
with the address of the second external station leaving at
0 microswitches SW2 (see table on page 39) and press
for a long time key
occurred storing of the second address. Proceed in a
similar manner to the programming of the third and fourth
external station address, the occurred programming is
confi rmed respectively by three or four tones.
To change the stored addresses, it is necessary to exit
from the programming, wait 3 seconds and re-enter in
programming; with SW1 set the new address, leaving
SW2 at 0 and press for a long time key
will confi rm the occurred storing of the new fi rst address;
proceed in a similar manner to change the eventual second,
third and fourth address. To delete the stored addresses, it
is necessary to set code 255 on SW1 and 0 on SW2 (see
table on page 39) and press for a long time key
a tone will confi rm the occurred cancellation of the fi rst
address; proceed in a similar way to cancel any second,
third and fourth stored address.
4.1.3 Addresses associated to
To key
can be associated 1 address of apartment and
of room for intercommunicating calls, or 1 actuator address.
- Programming Building Intercommunicating Address:
with microswitches SW1 set the address of the desired
apartment and with microswitches SW2 set the room
number 0 (see table on page 39); press for a long time
key
until a tone will confi rm the occurred storing.
- Programming Apartment Intercommunicating Address:
with microswitches SW1 set the address of your apartment
and with microswitches SW2 set room number, from 0 to
3 (see table page 39); press for a long time key
a tone will confi rm the occurred storing.
- Programming Actuator Address:
with microswitches SW1 set the actuator address that it is
intended to control (from 211 to 230) and with microswitches
SW2 set the room number 0 (see table on page 39);
press for a long time key
occurred storing.
To change the stored address, it is necessary to set with
SW1 and SW2 the new codes and press for a long time key
until a tone will confi rm the occurred storing; instead
to delete the stored address, it is necessary to set code
255 on SW1 and 0 on SW2 (see table on page 39) and
press for a long time key
occurred cancellation.
4.1.4 Forwarding a fl oor call
Upon arrival of a call from a fl oor, only the monitor to which
the call pushbutton is connected rings. If it is intended to
relaunch the call also on all the other monitors present in
the apartment or in another apartment, it is necessary to
proceed as follows:
- with microswitches SW1 set the address of the main
video intercom of the apartment to which it is intended to
- 15 -
until a tone will confi rm the occurred
until two tones will confi rm the
until a tone
key
until a tone will confi rm the
until a tone will confi rm the
until
until
Mi 2515

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Zheros zh1252wZheros zh1252b

Inhaltsverzeichnis