Herunterladen Diese Seite drucken

Device Description; Start-Up; Operation; Suction Process - Kärcher IVR-L 40/12-1 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für IVR-L 40/12-1:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
DANGER
Danger of electric shock
Danger of death
Avoid damaging the power cables by driv-
ing over them or otherwise crushing them,
or by jerking them.
Protect the cables from heat, oil and sharp
edges.
Check the mains connection of the device
for damage every time before operation.
Do not operate the device using a damaged
cable. Have any damaged cables replaced
by a qualified electrician.
Symbols on the device
Marking the maximum permissible fluid
level
See chapter Checking the filling level dis-
play.
ATTENTION
Risk of damage to the device
Leaking water due to the maximum fluid
level being exceeded.
Drain the device before the maximum fluid
level is reached.

Device description

See graphics page for illustrations
Illustration A
Steering rollers with parking brake
1
Maximum filling level mark
2
Drain hose
3
Liquid container
4
Push handle
5
Deflector plate
6
Small deflector plate
7
Filter
8
Suction head
9
Suction hose connection
10
Power switch
11
Suction head lock
12
Mains cable
13
Liquid container crane grommet
14
Tilting chassis
15
Accessory holder
16
Unlocking lever
17
14
See graphics page for illustrations
1. Bring the device into the working posi-
tion.
2. If necessary, secure the device using the
parking brake.
3. Ensure that the suction head is fitted
correctly.
4. Insert the suction hose into the suction
hose connection.
Illustration B
5. Plug the desired accessory onto the suc-
tion hose.
See graphics page for illustrations
1. Plug the mains plug into the socket.
2. Switch on the device using the power
switch.
Illustration C
Device with a motor (IVR-L...-1)
Illustration D
Device with two motors (IVR-L...-2)
ATTENTION
Operation with a motor
Risk of damage to the drive motor
Switch between the level settings quick-
ly.
The switch has multiple level settings:
0The device is off.
1Motor 1 is switched on.
2Motors 1 and 2 are switched on.
3. Start vacuuming.

Suction process

Note
Only immerse the accessory halfway when
vacuuming liquids to encourage sufficient
air.
English