Connections

p Turn off the power of all the equipment before proceeding with the connections.
p Connect the AC power cable supplied with the indoor pan-tilt head (AW-PH405) for the AW-PH405.
p Use 10BASE-T straight cables to connect the RP connectors on the pan-tilt heads with the CONTROL OUT TO PAN/TILT
HEAD (1 to 5) connectors on the multi-function controller (AW-RP655) and multi hybrid control panel (AW-RP555).
The maximum extension distance is 1000 meters when using UTP category 5 cables or their equivalent.
p Use the camera cables supplied with the pan-tilt head to connect the AW-PH405 to the convertible camera.
p Connect the iris control cable of the motorized zoom lens to the IRIS connector on the camera, and connect the zoom/focus
cable to the LENS I/F (1) connector on the pan-tilt head.
For a convertible camera
10BASE-T
straight cable
AW-RP555
Multi Hybrid Control Panel
AW-RP655
Multi-Function Controller
AW-CB400
Remote Operation
Panel
Motorized zoom lens
AW-PH405
Indoor Pan-tilt Head
Pan-tilt head/camera control signals
AW-PS505A
AC Adapter
AW-RP400
Pan/tilt Control Panel
27 (E)
To the
LENS I/F (1)
Zoom/focus
connector
control cable
AC power cable
supplied with
AW-PH405
• AW-IF400

Switch settings

AW-PS505A
AC Adapter
SW1
OFF
AW-PS505A
AC Adapter
Iris control cable
Camera cable
supplied with
AW-PH405
Convertible Camera
BNC cable video signal
Monitor
SET UP
SW2
1
2
3
4
ON
OFF
ON
OFF
OFF
AW-IF400
Protocol Converter
AW-PS505A
AC Adapter