Herunterladen Inhalt Inhalt Diese Seite drucken

Panasonic AW-PH405E Handbuch Seite 10

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 34
Parts and their function
 ND/EXT connector [ND/EXT]
This is for the control of the ND filter and lens extender of
the motorized lens unit.
Connect this connector when using a motorized lens
unit with ND filter and lens extender functions. The cable
described in "Cable specifications" on page 29 is required
in order to connect this connector.
CanonEXT (U)
CanonEXT (T)
ND Signal
ND Return
(Pin layout as seen from cable end)
The current rating of the CVCC and CGND pins is
500 mA (max). Any devices whose maximum current
consumption exceeds 500 mA cannot be used.
 LENS I/F (2) connector [LENS I/F (2)]
This is used when an IAS, WAS or VAS lens made by
Canon or an RD lens made by Fujinon is to be used.
The optional connecting cable is required to connect the
lens with the connector.
The current rating of LENS I/F (2) connector is 500 mA
(max).
The lens whose maximum current consumption exceeds
500 mA cannot be used. Concerning the maximum
current consumption of the lens, contact the lens
manufacturer.
Lens
Canon
Digital
AW-CA4DLZG
Analogue
AW-CA4ALZG
Fujinon
AW-CA4FLZG
p Refer to the instructions for using the
Note
connecting cable to ensure that it is
connected properly.
Rotary head connector panel
CVCC (12 V)
CGND
EXT Return
EXT Signal
Cable
 LENS P/S ON/OFF switch [LENS P/S]
When this is set to ON, power is supplied to the lens from
the LENS I/F (1) connector. When it is set to OFF, power
is no longer supplied to the lens from the LENS I/F (1)
connector.
Set this switch to OFF when power is to be supplied from
a source outside the unit without using the AW-PH405's
dedicated camera cable.
 LENS I/F (1) connector [LENS I/F (1)]
This is used to control the zooming and focusing of the
motorized lens unit.
Use the motorized lens unit's remote (zoom/focus) control
cable to make the connection.
 CAMERA I/F connector [CAMERA I/F]
This is used for the control of the convertible camera.
Use the camera cable supplied with the AW-PH405 to
connect the connector with the REMOTE connector on
the camera.
Depending on the functions of the optional card, a special
camera cable (sold separately) is required.
 SDI IN connector [SDI IN]
Use a coaxial cable to connect this to the SDI OUT
connector on the SDI card (AW-PB504) or other card
installed in the convertible camera.
 AUX IN connector [AUX IN]
This connector is connected using a BNC coaxial cable
to the SDI OUT connector on the SDI card (AW-PB504)
or other card installed in the convertible camera or to the
VBS connector on the down converter board
(AK-HDC1500G) or other board installed in the multi
purpose camera (AK-HC1500G/AK-HC1800G).
 TALLY OFF/ON switch [TALLY]
When this is set to ON, the tally lamp is lit by the selected
signals. When it is set to OFF, the ( ) tally lamp will not
light even if the selected signals are supplied.
9 (E)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis