Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Aventics ES05 Betriebsanleitung

Ventilsystem
Vorschau ausblenden Andere Handbücher für ES05:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
AVENTICS | ES05 | R422003601–BAL–001–AB | English

10 Troubleshooting

Error
Possible cause
Valves do not switch.
Incorrect pilot air
configuration.
Valve does not switch.
Incorrect base
The following valve
plate used.
variants can be affected:
W
5/2 double solenoid
W
2x3/2
W
5/3
Valve system is leaky
Incorrect
tightening torque
or seals not fitted
properly.
Improperly
mounted
component.
If you cannot resolve a malfunction, please contact one of the addresses found under
http://www.aventics.com/contact.
11 Technical data, spare parts, and
accessories
Information on technical data, spare parts, and accessories can be found in the
online catalog (www.aventics.com/pneumatics-catalog).
Troubleshooting
Check your pilot air configuration
and if necessary apply pilot air to
connections X12 and X14.
Use a base plate for double
solenoid valves or exchange the
corresponding pilot blanking plate
with a pilot valve.
Check the tightening torques and
make sure the seals are
positioned correctly and
undamaged.
Check that the components (base
plates and valve functions) have
been mounted correctly (mounting
location/orientation).