Herunterladen Inhalt Inhalt Diese Seite drucken

Adjustments - Angelo Po 1G1FR4GD Bedien- Und Installationshandbuch

Gas-friteuse
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 59
3 - Check that the burner is switching on correctly
and its combustion.
4 - Check the gas pressure and flow-rate at mini-
mum and maximum settings and adjust if nec-
essary (see page 24)
5 - Check that the safety thermocouple is working
correctly.
6 - Check that there are no gas leaks.
Important
Before making any type of adjustment,
activate all the safety devices provided
and decide whether staff at work and
those in the vicinity should be in-
ADJUSTING GAS SOLENOID VALVE
IT
Important
GB
This adjustment is only required if the type
of gas to be connected is different from that
used for testing after the conversion proce-
DE
dure has been carried out (see page 23). Be-
FR
Carry out this operation as described on both the
gas solenoid valves.
ES
Natural gas
1 - Turn off the gas supply tap.
2 - Open the hatch (A).
3 - Undo the screw (B) of the pressure connection.
4 - Connect the pressure gauge (C) to the pres-
sure test point.
5 - Unscrew the cap (D) and if necessary fit the
spring (F) and adjuster screw (E) (supplied on
request).
6 - Turn the gas supply tap back on.
English

ADJUSTMENTS

RECOMMENDATIONS FOR ADJUSTMENTS
7 - Check that the nameplates specify the correct
gas for the country of use.
After testing, if necessary instruct the user in all the
skills necessary for putting the appliance into oper-
ation in conditions of safety, in accordance with le-
gal requirements.
formed. In particular, turn off the gas sup-
ply tap and prevent access to all devices
which might cause unexpected health and
safety hazards if turned on.
fore making this adjustment, check that the
gas supply pressure is the same as the rat-
ed pressure for the type of gas in use (see
table at back of manual).
A
C
B
- 24 -
8
D E F
IDM-39603311600.tif