Testing
A. After the isntallation, turn the detector on. After one minute of self-testing,
press the test button, walk in the scope of detection and watch the LED
indicator to make sure the detector is working.
B. The LED indicator blinks once when body movement is detected.
C. Adjust the detector angle to achieve the best detection performance.
Specifications
Power supply
DC 3V (AA 1.5V LR6 batteries x2)
Static current
≤ 30uA
Operating current
≤ 15mA
Detection scope
8m / 110°
Transmission distance
≤ 80 m (in open area)
Radio-frequency
433MHz (±75kHz)
Housing material
ABS plastic
Operating conditions
Temperature: -10°C~+55°C
Relative Humidity:
≤ 80% (non-condensing)
Detector dimensions (L x W x H)
107 x 53 x 32 mm
Bracket dimensions (L x W x H)
52 x 30 x 26.5 mm
34
Detection Scope
Top view
0m
2m
4m
2m
0m
Side view
110°
6m
8m