4
Optional sauna door
safety-monitor
2. The temperature is above 40°C:
If you quickly open the sauna door (for less than 5
seconds) no message will be indicated. If the sauna
door is opened for longer than 5 seconds:
•
you will hear a repeated beeping sound,
•
the heater will be turned off
•
the display 4 will indicate the message "door",
After closing the sauna door, the heater will be turned
on again.
•
the beeping stops,
•
the displayed message "door" disappears.
5
Pausing operation for a longer
time period
Turn off main fuse of the sauna control in the fuse
box.
26
Operating instructions for the user - Figure 5
6
Errors and possible remedies
6.1
Automatic time limitation
•
The sauna control turns off after 6 / 12 hours of
continuous heating (depending on factory set-
ting).
•
For continued operation press the START /
STOP 8 key.
6.2
Interior lighting does not work
•
Turn off ON / OFF 1 key.
•
Turn off main fuse of the sauna control in the
fuse box.
•
Replace light bulb.
•
Contact customer service or the electrical engi-
neer, if the interior light still does not work. (look
at part 1, chapter 7)
6.3
ERROR Display messages
The sauna control is not ready-to-operate:
1. Turn off main fuse of the sauna control in the
fuse box.
2. Contact customer service or the electrical engi-
neer.
3. Mark the device as "defective".
With the following display error messages 4 you can
inform customer service of possible errors/defects.
The error messages of the display mean:
E-F1:
Short-circuit or interrupted tempe
rature sensor line (white line)
E-24:
Excessive temperature fuse defect,
or (red) cable to excessive
temperature fuse interrupted.
E-P1:
Setting potentiometer for nominal
temperature defect.
E-51:
}
E-52:
Key 7 or 8 blocked
E-53: