Operation
2. Using the PLUS / MINUS keys 7 enter the desi-
red selected time, e.g. [02.30].
In 2 hours and 30 minutes the heater will start
heating.
3. Confirm the selected time with the START /
STOP 8 key.
The remaining time is shown in the display 4
with a flashing dot. (selected time = remaining
time until heater starts). After expiration of the
pre-section time the temperature measured in
the area of the temperature sensor is shown in
the display 4.
4. Set the desired temperature with the rotary knob
TEMPERATURE 6 in the range of
50 - 125 degrees Celsius.
5. To exit:
5.1 Press START / STOP 8 key.
The sauna heater turns off.
The display indicates 00.00 (Display blinks)
The signal lamp 3 HEATING goes out.
The control is ready for entering a selected time
or ready for a restart.
5.2 Press ON / OFF 2 key.
The sauna control is turned off.
NOTE:
The time needed for warm-up until the set temperature
of the heater is reached varies, depending on size of
sauna and type of stove.
NOTE:
The temperature indication at the position of the tem-
perature sensor differs very significantly from that of
the temperature in the area of the sunbed.
Operating instructions for the user - Figure 5
4
Optional sauna door
safety-monitor
To offer protection from fire hazards, the sauna door
will be monitored after the desired start-time has
been set (time until the stove turns on).
To prevent somebody from entering the cabin after
the desired start-time has been set, and perhaps
place an object on top of the stove, the control has
been equipped with a safety shutdown, which will
respond according to the operational status:
4.1
Operational status -
stove does not heat
The desired start-up time has been set. Heater is not
running yet. The sauna door is opened:
You will hear a repeated beeping sound,
the display 4 will indicate the message "door",
the desired start-time will be cancelled.
After closing the sauna door, you will have to re-enter
the desired start-time.
4.2
Operational status - stove is heating
The desired start-up time has elapsed. The heater is
running. The sauna door is opened:
1. The temperature is below 40°C:
You will hear a repeated beeping sound,
the display 4 will indicate the message "door",
After closing the sauna door, you will have to re-enter
the desired start-time or you will have to restart the
control .