Herunterladen Inhalt Inhalt Diese Seite drucken

Finishing The Assembly Of The Sauna Control; Optional Door Switch; Installing The Interior Temperature Sensor F I With Overtemperature Fuse - Sentiotec A2-15 Montage- Und Gebrauchsanweisung

Saunasteuerung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Assembling Instructions for Specialist Staff Only
3
Finishing the Assembly of the Sau-
na Control 3 6
1. Place top of enclosure 5 on top of the bottom of
the enclosure 1 rotate it to bottom and push until
you hear it lock.
4

Optional door switch

Mount the optional door switch according to the
assembling instructions attached to the door switch,
or in accordance with the specifications of the cabin
manufacturer.
20
5
Mount temperature sensor F I with
overtemperature fuse 4 6
Mount the temperature sensor F I with overtempera-
ture fuse in the sauna cabin about 15 cm below the
ceiling and above the heating system, or in accor-
dance with specifications of the cabin manufacturer.
The sensor F I can only be connected with the at-
tached 150°C temperature-resistant connecting line.
On the outside of the sauna cabin the temperature-
resistant connecting line can be extended with custo-
mary lines.
CAUTION - Double insulation is required:
The sensor lines have to run separately to other circuit
and control lines.
Single insulated lines have to be protected with a pipe
(double insulation).
1. Run two x two-pin line 5 to mounting site of sen-
sor FI 4 at the cabin wall and fix in position with
wiring clips.
2. Separate two half shells 1 of the sensor F I and
clamp to four terminal connectors of the tempe-
rature-resistant connection line according to the
circuit diagram.
3. Insert round adaptor plate 2 with the connection
cross-wise in the half shells, 1 close half shells
1 and tighten with the two recessed head screws
3 which are 9 mm in lenght.
Check for secure locking of the sensor F I.
4. Run tests according to chapter 6, "Tests".
5. Bolt sensor F I 4 with two wooden screws to
the cabin wall in aligment with the middle of the
heater, keep a distance of 15 cm to the ceiling,
or in accordance with specifications of the cabin
manufacturer.