Poor welding properties
Cause:
Incorrect welding parameters
Remedy:
Check the settings
Cause:
Poor connection to earth (ground)
Remedy:
Ensure good contact to workpiece
The welding torch becomes very hot
Cause:
The design dimensions of the torch are not sufficient for this task
Remedy:
Respect the duty cycle and loading limits
Cause:
Only on water-cooled machines: Water through-flow is insufficient
Remedy:
Check the coolant level, through-flow rate, cleanliness of coolant, arrangement of hose-
pack, etc. If the coolant pump is blocked: Use a screwdriver - placed on the bushing - to
turn the shaft of the coolant pump.
Weld-seam porosity
Cause:
Spatter accumulating in the gas nozzle, causing inadequate gas-shielding of the weld-
seam
Remedy:
Remove the welding spatter
Cause:
Either the shielding-gas hose has holes in it, or it is not connected up properly
Remedy:
Change the shielding gas-hose
Cause:
The O-ring seals on the connection points are cut or defective
Remedy:
Change the O-ring seals
Cause:
Moisture / condensate in the shielding-gas hose
Remedy:
Dry the shielding-gas hose
Cause:
Shielding-gas flow is either too high or too low
Remedy:
Correct the shielding-gas flow
Cause:
Insufficient shielding-gas flow at the beginning or end of welding
Remedy:
Increase the gas pre-flow or post-flow
Cause:
Only on welding torches with external wire feeding: The welding wire is rusty or of poor
quality
Remedy:
Use only high-quality wires that are free of contaminants
Cause:
Too much parting agent applied
Remedy:
Wipe off excess parting agent / apply less parting agent
Poor ignition properties
Cause:
Unsuitable tungsten electrode (e.g. WP electrode for DC welding)
Remedy:
Use suitable tungsten electrode
Cause:
Loose clamping nuts, gas lens or clamping sleeve
Remedy:
Tighten clamping nuts, gas lens or clamping sleeve
Cracks in gas nozzle
Cause:
Electrode does not protrude far enough out of gas nozzle
Remedy:
Allow electrode to protrude further out of gas nozzle