Description
The ZE5 electric panel is suitable for con-
trolling the automation of EMEGA (E300-
E450) series 230V garage-type doors with
up to 400W power and 50-60 Hz fre-
quency.
Wholly designed and built by CAME CAN-
CELLI AUTOMATICI S.p.A., it meets regu-
lations in force. ABS Case with an IP54
protective level.
The circuit should be powered with voltage
of 230V AC and it is protected in input with
5A fuse, whilst the command devices in
low voltage are protected by fuse 1,6 A.
The accessories' total wattage (24V) must
not exceed 20W.
Fixed operating time of 80 seconds.
Safety functions
Photocells can be connected to obtain:
- Re-opening during closure (2-C1), if the
photocells identify an obstacle while the
gate is closing, they will reverse the
direction of movement until the gate is
completely open;
- Total stop (1-2), shutdown of gate
movement without automatic closing; a
pushbutton or radio remote control must
be actuated to resume movement.
N.B: If an NC safety contact (2-C1, 1-2) is
opened, the LED (n°2, pag. 11) will flash to
indicate this fact;
- Obstacle presence detection. When the
motor is stopped (gate is closed, open or
half-open after an emergency stop
command), the transmitter and the control
pushbutton will be deactivated if an
obstacle is detected by one of the safety

GENERAL CHARACTERISTICS

devices (for example, the photocells);
- Detection of obstacle with Encoder. It is
activated for when an obstacle is
encountered during the movement of the
door and as a result:
a) the door stops if it is in the opening
phase, with subsequent automatic closing
(if activated);
b) the movement is reversed if it is in the
closing phase.
N.B.: In situation b, if an obstacle is
detected three times, the door wing stops
during aperture, and automatic closure is
disactivated.
Use the keyboard or the radio transmitter
to resume movement of the bar.
- Automatic closing . The automatic closing
timer is automatically activated at the end
of the opening cycle. The preset,
adjustable automatic closing time is
automatically interrupted by the activation
of any safety system, and is deactivated
after a STOP command or in case of
power failure;
- "Operator present" . The movement of the
door is obtained only by keeping pressed
the pushbutton of command connected on
terminals 2-7 or from the open pushbutton
on 2-3 (and it excludes the function with
the radio control);
- Limit switch opening. The door stops with
the help of the microswitch during the
opening phase, connect the microswitch to
terminal blocks 2-FA;
- Pre-flashing. After an opening or closing
command, the flasher connected to the W-
Other functions
-3-