Low Boy Bilge Pump
Low Boy - low profile pump
designed for ease of mounting and
removal in tight bilge areas. Perfect
for vessels with bilge pumps
mounted beneath inboard or I/O
engines. Removable cartridge
style. 500-1000 GPH: Easy-to-
install Dura-Port discharge ports to
eliminate stress cracking caused
by over-tightened hose clamps.
The pumps include both a straight
and a 90° smooth elbow Dura-Port
as well as a removable check valve.
Max Length: 146 mm – 5.75"
Width: 81 mm – 3.2"
Height: 72 mm – 2.82"
Wire size: 1.3 mm

Installation Instructions

1.
Mount pump at lowest point
in the bilge.
2.
Select a point where bilge
water is to be pumped over-
board, at least 1 foot above
the waterline and the shortest
distance from the pump.
500-1000 GPH: Install a
19 mm (3/4") thru hull.
1250 GPH: Install a 28 mm
(1 1/8") thru hull. The pump
can be mounted horizon-
tally or vertically, however
the pump does need to be
installed in the lowest part of
the bilge.
6
– 16 GA
2
Wiring the pump
1. Connect the brown wire from
the pump to the positive (+)
fused side of the battery.
2. Connect the black wire coming
off of the pump to the negative
(-) side of the battery.
3. Do not cut any wire insulation
more than 3" and keep all con-
nection above the water levels,
keep all connections high and
dry. A marine grade sealant/
liquid electrical tape is
recommended to seal loose
wire ends. A submerged splice
will render the warranty void.
4. Fuse all cartridge style pumps
at 5A.
5. Do not run pump dry for more
than 10 seconds.
6. If you are using a float switch
in conjunction with this pump,
be sure that the float switch is
higher than the impeller level
of the pump to assure proper
shutoff of the pump.